Notifier FPC-951 Addressable Multi-Criteria Photo and Carbon Monoxide Detectors
FPC-951 and FPC-951A are intelligent, addressable smoke and carbon monoxide (CO) detectors with integral communication to provide point location for alarm communication and selective maintenance.
These detectors have point ID capability that enables each detector address to be set with rotary address switches providing exact device locations. The modern design and expanded color options support contemporary aesthetic demands.
In addition, each detector is constructed for exceptional installation and maintenance efficiency.
FPC-951 is an intelligent, multi-criteria detector that incorporates photoelectric and carbon monoxide (CO) detection principles.
FPC-951 offers a cost-effective solution meeting both the UL 268 7th edition standard for smoke detection and UL 2075 standard for system-connected life safety carbon monoxide detection.
FPC-951A meets CAN/ULC-S529 and CAN/ULC-S588. The dual function of this single device makes it ideal for installations such as hotels, schools and high-rise residential applications that require both smoke and CO detection.
Released through the incomplete burning of various fuels, CO is a colorless, odorless and deadly gas that is virtually impossible to detect with the human senses. Because the potential exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to grow.
FPC-951 is recommended for use in conjunction with the B200S series intelligent sounder bases.
For Canadian applications, use B200SCOA series with FPC-951A. These bases can generate either a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm
indication.
The B200S series bases recognize the System Sensor synchronization protocol. This enables it to be used as a component of the general evacuation signal — along with other System Sensor horns, horn strobes, and chimes — when connected to a power supply or Fire Alarm Control Panel (FACP) output capable of generating the System Sensor synchronization pulses.
Features and Benefits
• Combination smoke and CO detector
• Automatic drift compensation of smoke sensor and CO cell
• Uses only one address on the SLC
• RealTest® CO testing capability
• UL 268 7th edition and UL 2075 listed
• Canadian standards CAN/ULC-S529 and CAN/ULC-S588
• Separate audible signal for fire or CO alarm when used with a
B200S/B200SCOA series base
• 10-year CO cell with end-of-life warning and fault
• New modern profile
• Expanded color options
Detector Specifications
PHYSICAL SPECIFICATIONS
Height: 2.7 in. (69 mm) installed in B200S series sounder base
Diameter: 6.875 in. (175 mm) installed in B200S series sounder bases
Weight: 3.4 oz. (95 g)
Color: White
Operating Humidity Range: 15% to 90% Relative Humidity, Noncondensing
Operating Temperature Range: 32°F to 122°F (0°C to 50°C)
Air Velocity: 0 to 4000 ft./min. (0 to 1219.2 m/min.)