BRK SMI100 (cat. 1046832) is a battery-operated residential smoke alarm with an ionization sensing chamber and a 9V battery. The front-door battery compartment allows battery replacement without taking the alarm down, and a battery pull tab keeps the battery fresh until the home is occupied. One Test/Silence button checks all alarm functions by simulating a smoke condition and also silences unwanted nuisance alarms. The SMI100 is discontinued; the First Alert SM601 is its replacement.
Specifications
| Sensor |
Ionization |
| Power |
9V battery (included), no hardwiring |
| Horn |
Solid-state piezo, 85 dB at 10 ft |
| Dimensions |
5.58" diameter x 1.99" H |
| Weight |
0.43 lb |
| Temperature range |
40°F (4.4°C) to 100°F (37.8°C) |
| Humidity range |
10% to 95% RH |
| Test/Silence |
Electronically simulates smoke, causing the unit to alarm |
| Alarm reset |
Automatic when smoke clears |
| Indicators |
Power: green flash every minute; alarm: 3 beeps and red flash; low battery: 1 chirp per minute; malfunction: 3 chirps per minute; end of life: 5 chirps per minute |
| Certification |
UL 217 |
| Warranty |
10-year limited |
Installation notes
- Designed for ceiling mounting, or wall mounting where allowed by building codes.
- On ceilings, install as close to the center as possible, or at least 4 in (102 mm) from the wall or corner.
- On walls, place the top edge 4 to 12 in (102 to 305 mm) below the wall/ceiling line.
- On peaked, gabled or cathedral ceilings, install the first alarm within 3 ft (0.9 m) of the peak, measured horizontally.
- Battery-operated alarms do not interconnect; use an AC-powered model where interconnection is required.
- Tamper-resistant locking pins can lock the battery drawer and/or the alarm to the mounting bracket.
- Replace the alarm 10 years after installation.
Related models
-
SM601 — First Alert battery-powered smoke alarm, the replacement for the SMI100
-
SMI100-AC — BRK hardwire interconnect smoke alarm with battery backup
Documents
FAQ
Is the SMI100 still available, and what replaces it?
The SMI100 is discontinued. The First Alert SM601 battery-powered smoke alarm is its replacement.
Can the SMI100 be interconnected with other alarms?
No. The BRK manual states that battery-operated smoke alarms do not provide interconnected functionality. AC-powered alarms such as the SMI100-AC can be interconnected.
What type of sensor does it use?
An ionization sensing chamber, with a piezo horn rated 85 dB at 10 ft.
When should the alarm be replaced?
Replace it 10 years after installation. The alarm also gives an end-of-life signal of 5 chirps every minute.