SMCO600NV-AC — First Alert SC5 Wired Smart Smoke & Carbon Monoxide Alarm, a 120VAC hardwired combination smoke and CO alarm with voice alerts, hardwire interconnect and app connectivity.
The SC5 wired alarm is intended for single-family residences and is installed on a junction box using the supplied mounting bracket and a Quick-Connect power connector, so an existing compatible alarm can be swapped without rewiring. It must be fed from a 24-hour 120VAC pure sine wave 60Hz circuit that cannot be switched off by a switch, dimmer or GFCI. Battery back-up is shipped with a pull tab in place and is activated by removing that tab during installation. Voice alerts announce the type of danger and the programmed location, and the alarm reports to a phone through the First Alert by Resideo app.
Specifications
| Model |
SMCO600NV-AC (SC5 Wired) |
| Detection |
Combination smoke and carbon monoxide |
| Power source |
24-hour 120VAC pure sine wave 60Hz circuit, with battery back-up |
| Circuit restrictions |
Circuit must not be controlled by a switch, dimmer or ground fault circuit interrupter |
| Interconnect |
Hardwire, via orange interconnect wire on the power connector |
| Maximum interconnected units |
18 compatible units, of which a maximum of 12 may be smoke alarms |
| Maximum interconnect wire length |
Less than 1000 ft (300 m) total |
| Wireless frequency |
2.4GHz and 5GHz; 802.11 b/g/n/ac router recommended |
| End-of-life signal |
Audible signal approximately 10 years after installation |
| Mounting |
Mounting bracket with Quick-Connect power connector; ceiling or wall |
| Approved use |
Single-family residences; not designed for marine or RV use |
Installation notes
-
Dedicated 24-hour circuit: the manual specifically requires a circuit that cannot be turned off by a switch, dimmer or GFCI. Feeding the alarm from a switched or GFCI-protected circuit may prevent it from providing constant protection.
-
Pure sine wave only: AC-powered alarms should only be operated with true or pure sine wave inverters. Most battery-powered UPS units are not suitable.
-
Orange wire is interconnect only: never connect the hot or neutral wires in the junction box to the orange interconnect wire. On a stand-alone install, tuck the orange wire into the junction box unused.
-
Same breaker: all interconnected units must be powered from the same fuse or circuit breaker.
-
Activate the back-up battery: remove the battery tab during installation, or the unit will not be protected during a power outage.
-
Test individually: when testing an interconnected series, each unit must be tested separately and every unit must sound.
-
Interconnect within one dwelling: interconnect only within a single-family residence, or all households will experience unwanted alarms during testing.
-
Smart Interconnect: alarms without the Smart Interconnect feature will remain silent during a CO alarm, even when interconnected.
Related models
-
SMCO600NV — the battery-powered SC5. It is powered by six 3V CR123A batteries and interconnects wirelessly through the app rather than over an orange interconnect wire; it has no AC connection and none of the hardwire interconnect limits above apply to it.
-
SMICO100-AC, SC7010BV, SC9120B — earlier First Alert / BRK hardwired smoke and CO alarms listed as compatible for interconnection with this unit.
-
SMI100-AC, SM100V-AC, 9120B, 7010B — compatible hardwired smoke-only alarms for the same interconnect series.
-
HD6135FB — BRK heat alarm listed as compatible for interconnection.