{"product_id":"resideo-sv9520h8513-u-1-2-npt-direct-hot-surface-ignition-smartvalve-control-sv9520h8513","title":"Resideo SV9520H8513\/U 1\/2\" NPT Direct Hot Surface Ignition SmartValve Control, SV9520H8513","description":"1\/2 in. NPT x 1\/2 in. NPT Direct Hot Surface Ignition SmartValve Control with fast-slow opening and 3.5 in. wc pressure regulator setting\r\n\u003cbr\u003e\u003cbr\u003e\u003cb\u003eNote: This model includes an LP Conversion Kit\u003c\/b\u003e\r\n\r\n\u003cbr\u003e\u003cbr\u003e\r\n\u003cb\u003eProduct Line Overview\u003c\/b\u003e\u003cbr\u003eThe SV9520 SmartValve System Controls combine gas flow control and electronic direct main burner ignition sequencing functions into a single unit.\u003cbr\u003e\u003cbr\u003e\r\n\r\n\u003cb\u003eFeatures\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eThe control communicates directly with the ST9160 Electronic Fan Timer (EFT) in typical forced warm air furnace applications. \u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eIt will also interface with the 208907 Terminal Board, providing compatibility with power-stealing thermostats. Or, it directly interfaces with the appropriate power supplies and a system thermostat for additional appliance applications. \u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eWhen controlled directly by a thermostat, the control does not provide a postpurge function, as power to the control is removed when the thermostat call for heat ends. \u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eThis system is suitable for a wide range of fan-assisted combustion, gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances. \u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e Flame Sense: Two Rod\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Type of Gas: Natural\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Ignition System Type: Direct Hot Surface Pilot Ignition\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Ignition Sequence: 7\/12 sec\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Ignition Trials To Lockout: 4 trials\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e PrePurge: 15 seconds\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Body Pattern: Straight-through \u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Opening Characteristics (standard, step): Fast Slow Opening \u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Control Voltage (Thermostat or other call for heat): 24 Vac, 60 Hz \u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Ignition Trial Time (sec): 90 Sec \u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Electrical Ratings: 24 Vac \u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Frequency: 50 Hz\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Flame Failure Response Time (sec): 2 sec @ 5 µA\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Ambient Temperature Range (F): 0 F to +175 F\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Ambient Temperature Range (C): -18 C to +79 C\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Dimensions (in.): 3.2 in. wide x 4.9 in. high x 4.1 in. long\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Dimensions (mm): 81 mm wide x 124 mm high x 104 mm long\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Pressure Regulator Setting (psi): 3.5 in. wc\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Pressure Regulator Setting (kPa): 0.87 kPa\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Pressure Ratings (psi): 1\/2 psi\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Pressure Ratings (kPa): 3.5 kPa\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Inlet\/Outlet Size (in.): 1\/2 in. NPT x 1\/2 in. NPT \u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Maximum Capacity (ft³\/hr): 200 ft³\/hr\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Maximum Capacity (m³\/hr): 5.7 m³\/hr\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Minimum Capacity (ft³\/hr): 20 ft³\/hr\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Minimum Capacity (m³\/hr): 0.6 m³\/hr\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Maximum Capacity at 1 in. P.D. (ft³\/hr): 150 ft³\/hr\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Maximum Capacity at 1 in. P.D. (m³\/hr): 4.2 m³\/hr\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Pressure Tapping: 1\/8 in. - NPT\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Approvals, Canadian Standards Association: CSA International: 158158-10592145 \u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003e Tradeline Value: Super Tradeline\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":53777500700896,"sku":"SV9520H8513\/U","price":610.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/259273736.jpg?v=1785764364","url":"https:\/\/thefirealarmsupplier.com\/products\/resideo-sv9520h8513-u-1-2-npt-direct-hot-surface-ignition-smartvalve-control-sv9520h8513","provider":"The Fire Alarm Supplier","version":"1.0","type":"link"}