{"product_id":"fire-lite-prn-7-24-pin-dot-matrix-event-printer-80-column-110-230-vac","title":"Fire-Lite PRN-7 24-Pin Dot-Matrix Event Printer, 80 Column, 110-230 VAC","description":"\u003cp\u003e\u003cstrong\u003ePRN-7\u003c\/strong\u003e is a 24-pin dot-matrix event printer used with Fire-Lite fire alarm control panels that have printer capability. It produces a time- and date-stamped hard copy of system events and status changes, along with printouts of the system configuration and addressable device parameters. On Fire-Lite MS-5UD and MS-10UD panels it connects through the ANN-S\/PG serial\/parallel printer gateway module.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial printing, 24-pin matrix print head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrinting speed (copy draft)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e333 cps at 10 cpi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacter density\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 cpi standard; 12, 15, 17.1 and 20 cpi selectable from the front panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColumns\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 columns at 10 characters per inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGraphic resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 360 x 360 dpi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePaper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 9 in. x 11 in. tractor-feed fan-fold paper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRibbon life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 6 million characters (DPQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAcoustic noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 52 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110-230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate enclosure for desktop, counter or table placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL-listed compatible event printer (per Fire-Lite MRP-2002 data sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall no more than 20 ft (6.10 m) of actual cable length from the fire alarm control panel, in a secure area.\u003c\/li\u003e\n\u003cli\u003eOn MS-5UD\/MS-10UD panels, connect to the ANN-S\/PG module with a standard DB-9 cable and set the printer options listed in the panel manual (for example 9600 or 2400 baud, 7 bit, even parity, 1 stop bit, XON\/XOFF).\u003c\/li\u003e\n\u003cli\u003eThe printer needs primary AC power; where a secondary power source is required, use a separate UL-listed UPS or building emergency power that meets NFPA 72.\u003c\/li\u003e\n\u003cli\u003eListed as a compatible event printer for the Fire-Lite MRP-2002(E) agent release control panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/fire-lite-ann-s-pg\"\u003eFire-Lite ANN-S\/PG Serial\/Parallel Printer Gateway Module\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/prod-edam.honeywell.com\/content\/dam\/honeywell-edam\/hbt\/en-us\/documents\/literature-and-specs\/datasheets\/9021-60901.pdf\"\u003ePRN-7 Printer Data Sheet 9021-60901 Rev. A (Honeywell\/Gamewell-FCI)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/prod-edam.honeywell.com\/content\/dam\/honeywell-edam\/hbt\/en-us\/documents\/literature-and-specs\/datasheets\/df-60238.pdf\"\u003eMRP-2002(E) Agent Release Control Panel Data Sheet DF-60238:C3 (Fire-Lite)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/prod-edam.honeywell.com\/content\/dam\/honeywell-edam\/hbt\/en-us\/documents\/manuals-and-guides\/user-manuals\/52626.pdf\"\u003eMS-5UD \u0026amp; MS-10UD Series Manual 52626:C7 (Fire-Lite)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from PRN-7 data sheet 9021-60901 Rev. A, Fire-Lite DF-60238:C3 and Fire-Lite manual 52626:C7. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":67753677783264,"sku":"PRN-7","price":2667.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/hbt-Fire-P1920104-primaryimage.jpg?v=1791291922","url":"https:\/\/thefirealarmsupplier.com\/products\/fire-lite-prn-7-24-pin-dot-matrix-event-printer-80-column-110-230-vac","provider":"The Fire Alarm Supplier","version":"1.0","type":"link"}