{"product_id":"fire-lite-mrp-2002e-agent-release-control-panel-6-zone-220-240-vac","title":"Fire-Lite MRP-2002E Agent Release Control Panel, 6 Zone, 220\/240 VAC","description":"\u003cp\u003e\u003cstrong\u003eMRP-2002E\u003c\/strong\u003e is the 220\/240 VAC version of the Fire-Lite MRP-2002 six-zone agent release control panel. It is a conventional fire alarm control panel for single and dual hazard agent releasing applications, designed for agent releasing standards NFPA 12, 12A, 12B and 2001. Apart from the AC input, Fire-Lite states it has the same features as the 120 VAC MRP-2002.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP-2002E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 VAC, 50\/60 Hz, 2.085 A (FLPS-7 power supply); minimum #14 AWG wire with 600 V insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitiating device circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 programmable Style B (Class B), Style D (Class A) with optional CAC-5X; 4.7K ohm end-of-line resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, programmable as NACs or releasing circuits, Style Y (Class B) or Style Z (Class A) with converter module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal 24 VDC output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 A (3.0 A special application, 300 mA regulated maximum per NAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 programmable Form-C (default Alarm, Trouble, Supervisory); 2 A @ 30 VDC, 0.5 A @ 30 VAC resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResettable and resettable\/nonresettable 24 VDC outputs, 500 mA each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.6 VDC @ 1.4 A; 7 Ah minimum, 26 Ah maximum (two 18 Ah batteries fit in the cabinet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80-character backlit LCD, real-time clock, 256-event history log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnnunciators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 ANN-BUS devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrobe synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Sensor, Wheelock, Gentex, Faraday, Amseco\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet backbox\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.00 in. H x 16.65 in. W x 5.25 in. D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 to 120°F (0 to 49°C), 93% ± 2% RH noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 864 9th edition (UL S624), FM approved, CSFM 7165-0075:0216, MEA 333-07-E; IBC seismic with SEISKIT-COMMENC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWorks with System Sensor i3 conventional detectors and with two-wire and four-wire smoke detectors, pull stations, waterflow and tamper switches; see the Fire-Lite Device Compatibility Document for listed devices.\u003c\/li\u003e\n\u003cli\u003eIncludes cross-zone (double interlock), dual hazard operation, and adjustable pre-discharge, discharge and waterflow delay timers.\u003c\/li\u003e\n\u003cli\u003eOptions include DP-51050 dress panel, TR-CE trim ring for semi-flush mounting, CAC-5X Class A converter, 4XTMF transmitter module, 411 series communicators and ANN-SEC card.\u003c\/li\u003e\n\u003cli\u003eBatteries larger than two 18 Ah units need a separate battery box such as BB-26 or BB-55.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fire-lite-mrp-2002\"\u003eFire-Lite MRP-2002\u003c\/a\u003e, 120 VAC version\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fire-lite-tr-ce\"\u003eFire-Lite TR-CE\u003c\/a\u003e trim ring\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fire-lite-4xtmf\"\u003eFire-Lite 4XTMF\u003c\/a\u003e transmitter module\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fire-lite-ann-80-lcd-serial-annunciator-red\"\u003eFire-Lite ANN-80\u003c\/a\u003e remote LCD annunciator\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fire-lite-ann-rly-10-relay-board\"\u003eFire-Lite ANN-RLY\u003c\/a\u003e relay module\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/fire-lite-bg-12lra-dual-action-agent-release-station\"\u003eFire-Lite BG-12LRA\u003c\/a\u003e agent release station\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/prod-edam.honeywell.com\/content\/dam\/honeywell-edam\/hbt\/en-us\/documents\/literature-and-specs\/datasheets\/df-60238.pdf\"\u003eFire-Lite MRP-2002(E) data sheet DF-60238:C3 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/buildings.honeywell.com\/us\/en\/products\/by-category\/control-panels\/fire-control-panels\/fire-alarm-control-panels\/mrp-2002-releasing-panel\"\u003eHoneywell product page, MRP-2002 Releasing Panel\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Fire-Lite data sheet DF-60238:C3 (3\/6\/2017). Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":67753670344928,"sku":"MRP-2002E","price":1565.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/hbt-Fire-P1903480-primaryimage.jpg?v=1791291904","url":"https:\/\/thefirealarmsupplier.com\/products\/fire-lite-mrp-2002e-agent-release-control-panel-6-zone-220-240-vac","provider":"The Fire Alarm Supplier","version":"1.0","type":"link"}