{"product_id":"fire-lite-ecc-50da-distributed-audio-amplifier-50w-120vac-for-ecc-50-100","title":"Fire-Lite ECC-50DA Distributed Audio Amplifier, 50W, 120VAC, for ECC-50\/100","description":"\u003cp\u003e\u003cstrong\u003eFire-Lite ECC-50DA\u003c\/strong\u003e is a 50 watt intelligent distributed (remote) audio amplifier for the Fire-Lite ECC-50\/100(E) Emergency Command Center. It is installed near the area it serves to amplify voice messages and tones when additional audio power is needed, reducing speaker circuit wiring runs. It has its own power supply and battery charger and is supervised by the ECC-50\/100 over the data bus and audio riser.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAudio power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 W, primary only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeaker voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 Vrms or 70.7 Vrms, field selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeaker circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour supervised Class B (Style Y) or Class A (Style Z), expandable to eight with ECC-CE4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz, 1200 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery charging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLead acid, 7 to 35 Ah; cabinet holds batteries up to 18 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 in. W x 26.25 in. H x 4.125 in. D (40.64 x 66.68 x 10.48 cm), surface or flush mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.8 lb (11.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 to 120 °F (0 to 49 °C), 93% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL S2424, CSFM 7300-0075:0227, FDNY COA #6152; UL 864, UL 2572\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCompatible only with the ECC-50\/100(E) Emergency Command Center.\u003c\/li\u003e\n\u003cli\u003eUp to eight ECC-50DA, ECC-50BDA or ECC-125DA amplifiers in any combination per system, for up to 1100 W and 24 speaker circuits.\u003c\/li\u003e\n\u003cli\u003eWired to the ECC-50\/100 data bus and audio riser; the amplifier must also be enabled in the ECC-50\/100 programming, where 70 V operation is set.\u003c\/li\u003e\n\u003cli\u003eFor batteries larger than 18 Ah use the BB-26 or BB-55F battery box.\u003c\/li\u003e\n\u003cli\u003eHoneywell lists the Intelligent Distributed Audio Amplifier family (ECC-50DA(E), ECC-50BDA, ECC-125DA(E)) as discontinued.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRelated models\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fire-lite-ecc-50-100-emergency-command-center\"\u003eECC-50\/100 Emergency Command Center\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fire-lite-ecc-50dae\"\u003eECC-50DAE export version, 240 VAC, 50 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fire-lite-ecc-125da\"\u003eECC-125DA 125 W distributed audio amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fire-lite-ecc-50bda\"\u003eECC-50BDA distributed audio amplifier with backup\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fire-lite-ecc-ce4-distributed-audio-speaker\"\u003eECC-CE4 circuit expander module\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fire-lite-bb-26-battery-backbox\"\u003eBB-26 battery box\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fire-lite-bb-55f-battery-box\"\u003eBB-55F battery box\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/prod-edam.honeywell.com\/content\/dam\/honeywell-edam\/hbt\/en-us\/documents\/literature-and-specs\/datasheets\/df-60763.pdf\"\u003eFire-Lite data sheet DF-60763, ECC-50DA(E), ECC-125DA(E), ECC-50BDA Distributed Audio Amplifiers (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/prod-edam.honeywell.com\/content\/dam\/honeywell-edam\/hbt\/en-us\/documents\/manuals-and-guides\/installation-guides\/LS10027-000FL-E.pdf\"\u003eFire-Lite manual LS10027-000FL-E, ECC-50\/125DA Instruction Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/buildings.honeywell.com\/us\/en\/products\/by-category\/fire-life-safety\/bi-directional-amplifiers\/power-amplifiers\/intelligent-distributed-audio-amplifier\"\u003eHoneywell product page, Intelligent Distributed Audio Amplifier\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eSpecifications from Fire-Lite data sheet DF-60763:C, 6\/30\/2015, and manual LS10027-000FL-E:D, 5\/21\/2015. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":67753670639840,"sku":"ECC-50DA","price":1370.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/hbt-Fire-P1901514-primaryimage.jpg?v=1791291912","url":"https:\/\/thefirealarmsupplier.com\/products\/fire-lite-ecc-50da-distributed-audio-amplifier-50w-120vac-for-ecc-50-100","provider":"The Fire Alarm Supplier","version":"1.0","type":"link"}