{"title":"Wires","description":"","products":[{"product_id":"macurco-cm-e1-harness-cm-e1-replacement-wire","title":"Macurco CM-E1 Harness-CM-E1 Replacement Wire","description":"\u003ch2\u003eMacurco CM-E1 Harness-CM-E1 Replacement Wire Harness-8 Pin\u003c\/h2\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003cp\u003eReplacement 8-pin wire harness for the Macurco CM-E1 carbon monoxide detector. The CM-E1 is wired through an eight-conductor pigtail cable: the leads are spliced to the control panel wiring with wire nuts and the connector snaps into the mating connector on the back of the detector, so the detector can be installed or swapped without rewiring.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight-conductor pigtail harness with plug-in connector\u003c\/li\u003e\n\u003cli\u003eSnaps into the connector on the back of the CM-E1\u003c\/li\u003e\n\u003cli\u003eLeads splice to control panel wiring with wire nuts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible With\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003eMacurco CM-E1 carbon monoxide detector\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/macurco.com\/wp-content\/uploads\/2018\/05\/cm-e1_usermannual.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCM-E1 User Instructions (wiring diagrams for the pigtail cable)\u003c\/a\u003e (User Manual)\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Macurco","offers":[{"title":"Default Title","offer_id":43174446760160,"sku":"CM-E1 HARNESS","price":6.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/macurco-wire-default-title-macurco-cm-e1-harness-cm-e1-replacement-wire-31896874320096.jpg?v=1763280183"},{"product_id":"genesis-43061004-18-2-solid-fire-alarm-riser-unshielded-red-1000-reel","title":"Genesis 43061004 18\/2 Solid Fire Alarm Riser Unshielded Red 1000 Reel","description":"\u003ch2\u003eGenesis 43061004 18\/2 Solid Fire Alarm Riser Unshielded Red 1000 Reel\u003c\/h2\u003e","brand":"Genesis","offers":[{"title":"Default Title","offer_id":47883888427232,"sku":"43061004","price":191.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/genesis-wires-default-title-genesis-43061004-18-2-solid-fire-alarm-riser-unshielded-red-1000-reel-39273243902176.webp?v=1763288469"},{"product_id":"thermocable-a1541-100","title":"Thermocable A1541-100 J-Lock Ceiling\/Wall Clip (50mm) for Linear Heat Detection Cable, Stainless Steel (pack of 100)","description":"\u003cp\u003e\u003cstrong\u003eThermocable A1541-100\u003c\/strong\u003e — stainless steel J-Lock ceiling and wall clip for fixing Thermocable ProReact linear heat detection (LHD) cable.\u003c\/p\u003e\u003cp\u003eThermocable quotes BS 5839-1 clause 26.2 f, which requires cable supports that are non-combustible and last as long as the cable in a fire, ruling out plastic clips, ties or trunking as the support. Its cold storage guide recommends stainless steel J-lock clips fitted with silicone sleeves.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaterial: stainless steel\u003c\/li\u003e\n\u003cli\u003eCold storage: robust support below freezing, fast fitting and removal, can be pre-installed\u003c\/li\u003e\n\u003cli\u003eCold storage spacing: fixings no more than 1 m apart; 150 mm (6 in.) minimum cable bend radius\u003c\/li\u003e\n\u003cli\u003eThermocable rates its stainless clips for indoor, outdoor and harsh-chemical use\u003c\/li\u003e\n\u003cli\u003eSilicone sleeve sold separately as C1283: 25 × 6 mm, 180 °C continuous\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe Thermocable 2024 Accessories Guide does not list the A1541 number. Its documented 50 mm stainless clip is the A1149-100 Standard J Clip (50 × 20 mm, one hole), and A1329-100 is the stainless P-clip. Confirm clip size against your cable and fixing surface before ordering.\u003c\/p\u003e","brand":"Thermocable","offers":[{"title":"Default Title","offer_id":48201492824288,"sku":"A1541-100","price":86.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/vesda-fire-alarms-default-title-vesda-vsp-1004-40062244094176_8cc0a5ec-2f72-47c6-bf7f-9d880a65cf8b.webp?v=1764878886"},{"product_id":"thermocable-a1329-100","title":"Thermocable A1329-100 Surface P-Clip Stainless Steel (pack of 100)","description":"\u003cp\u003eSurface P-Clip Stainless Steel (pack of 100)\u003c\/p\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003cp\u003eThe Thermocable A1329 is a stainless steel P-clip for surface-fixing ProReact linear heat detection cable, supplied in packs of 100. Thermocable states its stainless steel clips are suitable for indoor and outdoor use, including locations where the clip may be exposed to harsh chemicals such as hydrocarbons or a caustic environment. A silicone sleeve is used between the clip and the cable to protect it from abrasion, pressure and heat transfer from the metal fixing.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel P-clip for surface mounting of linear heat detection cable\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor and outdoor use and chemically harsh environments (per manufacturer)\u003c\/li\u003e\n\u003cli\u003eNon-combustible metal fixing, in line with BS 5839-1 guidance on cable supports cited by the manufacturer\u003c\/li\u003e\n\u003cli\u003eHigh-temperature silicone sleeves are packaged as standard with clips\u003c\/li\u003e\n\u003cli\u003eSupplied as a pack of 100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSize\u003c\/th\u003e\n\u003ctd\u003e12 mm x 22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003eUp to 815°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePack quantity\u003c\/th\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePack weight (net \/ gross)\u003c\/th\u003e\n\u003ctd\u003e340 g \/ 355 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatible With\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermocable ProReact Digital linear heat detection cable\u003c\/li\u003e\n\u003cli\u003eThermocable ProReact Analogue linear heat detection cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.thermocable.com\/downloads\/30\/ProReact%20Accessories%20Guide%202024.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProReact Accessories Guide (Rev 3.1, Feb 2024)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Thermocable","offers":[{"title":"Default Title","offer_id":48201492857056,"sku":"A1329-100","price":102.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/vesda-fire-alarms-default-title-vesda-vsp-1004-40062244094176_a260911a-ad19-4a06-9d3a-38a782590b7d.webp?v=1764878889"},{"product_id":"thermocable-a1388","title":"Thermocable A1388 J-Lock Ceiling\/Wall Clip (50mm) Stainless Steel (pack of 100)","description":"\u003cp\u003eJ-Lock Ceiling\/Wall Clip (50mm) Stainless Steel (pack of 100)\u003c\/p\u003e","brand":"Thermocable","offers":[{"title":"Default Title","offer_id":48201492922592,"sku":"A1388","price":873.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/vesda-fire-alarms-default-title-vesda-vsp-1004-40062244094176_2ab8bd98-ac64-4286-9a3c-b95da81cdcae.webp?v=1764878893"},{"product_id":"thermocable-f1065","title":"Thermocable F1065 UL Digital Linear Heat Cable 88C Degrees Nylon 500ft Spool","description":"\u003cp\u003eUL Digital Linear Heat Cable 88C Degrees Nylon 500ft spool\u003c\/p\u003e","brand":"Thermocable","offers":[{"title":"Default Title","offer_id":48201492955360,"sku":"F1065","price":516.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/vesda-fire-alarms-default-title-vesda-vsp-1004-40062244094176_e4e5d595-113a-4aec-933b-a344dee618d1.webp?v=1764878895"},{"product_id":"thermocable-f1070","title":"Thermocable F1070 UL Digital Cable 68C Degree Nylon (500 ft Spool)","description":"\u003cp\u003eUL Digital Cable 68C Degree Nylon (500 ft spool)\u003c\/p\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003cp\u003eThermocable F1070 is a ProReact Digital fixed-temperature linear heat detection cable with a 68°C (155°F) action temperature and a nylon outer sheath. The cable is a twisted pair of low-resistance tri-metallic conductors insulated with a temperature-sensitive polymer; when any point along the cable reaches the action temperature the cores come into contact and signal an alarm. The nylon outer sheath is offered by Thermocable for more demanding or exposed locations, adding UV protection and durability for outdoor use. It connects to a conventional initiating circuit or to an addressable loop through a zone\/switch monitor.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFixed-temperature (digital) linear heat detection cable, action temperature 68°C (155°F)\u003c\/li\u003e\n\u003cli\u003eMaximum ambient temperature 45°C (113°F)\u003c\/li\u003e\n\u003cli\u003eNylon outer sheath for UV protection and added durability outdoors\u003c\/li\u003e\n\u003cli\u003eTwisted pair of low-resistance tri-metallic conductors in temperature-sensitive polymer\u003c\/li\u003e\n\u003cli\u003ecUL\/UL 521 approved (File S8976) and FM approved (Class 3210); CE marked, RoHS compliant\u003c\/li\u003e\n\u003cli\u003eUp to 10,000 ft (3,000 m) per zone\u003c\/li\u003e\n\u003cli\u003eNon-restorable: a section that has alarmed is cut out and replaced\u003c\/li\u003e\n\u003cli\u003eCompatible with the ProReact Digital Interface Monitor Module (distance-to-alarm display)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAction temperature\u003c\/th\u003e\n\u003ctd\u003e68°C (155°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum ambient temperature\u003c\/th\u003e\n\u003ctd\u003e45°C (113°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum operating temperature\u003c\/th\u003e\n\u003ctd\u003e-40°C (-40°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter sheath\u003c\/th\u003e\n\u003ctd\u003eNylon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum voltage rating\u003c\/th\u003e\n\u003ctd\u003e30 VAC, 42 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResistance\u003c\/th\u003e\n\u003ctd\u003eApprox. 100 ohms\/km (30.4 ohms\/kft) per leg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum bend radius\u003c\/th\u003e\n\u003ctd\u003e50 mm (2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum zone length\u003c\/th\u003e\n\u003ctd\u003e3,000 m (10,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e0% to 100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupport spacing\u003c\/th\u003e\n\u003ctd\u003eEvery 1 m to 1.5 m (3 ft to 5 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpool length\u003c\/th\u003e\n\u003ctd\u003e500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatible With\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConventional fire alarm panel initiating device circuits\u003c\/li\u003e\n\u003cli\u003eAddressable loops via a zone\/switch monitor module\u003c\/li\u003e\n\u003cli\u003eThermocable ProReact Digital Interface Monitor Module (A1349)\u003c\/li\u003e\n\u003cli\u003eProReact fixing clips and accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.thermocable.com\/downloads\/32\/ProReact-Digital-LHD-Cable-Installation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProReact Digital LHD Cable Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.thermocable.com\/downloads\/79\/ProReact%20UL%20Fixed%20Temperature%20Activation%201pp%206_1_25.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProReact UL Fixed Temperature Activation Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.thermocable.com\/downloads\/31\/ProReact%20Digital%20LHD%20Cable%20Brochure.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProReact Digital LHD Cable Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.thermocable.com\/downloads\/30\/ProReact%20Accessories%20Guide%202024.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProReact Accessories Guide (Rev 3.1, Feb 2024)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Thermocable","offers":[{"title":"Default Title","offer_id":48201493053664,"sku":"F1070","price":563.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/vesda-fire-alarms-default-title-vesda-vsp-1004-40062244094176_d04fe8e5-5b31-401c-b815-01e259faa5f1.webp?v=1764878899"},{"product_id":"thermocable-f1073","title":"Thermocable F1073 UL Digital Linear Heat Cable 88C Degrees Nylon (500 ft Spool)","description":"\u003cp\u003eUL Digital Linear Heat Cable 88C Degrees Nylon (500 ft spool)\u003c\/p\u003e","brand":"Thermocable","offers":[{"title":"Default Title","offer_id":48201493119200,"sku":"F1073","price":563.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/vesda-fire-alarms-default-title-vesda-vsp-1004-40062244094176_afc2f7eb-4a41-422a-b7c2-e9364b3820ad.webp?v=1764878902"},{"product_id":"thermocable-f1124","title":"Thermocable F1124 UL Digital Plus 65C LSZH (500 ft Spool)","description":"\u003cp\u003eUL Digital Plus 65C LSZH (500 ft spool)\u003c\/p\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003cp\u003eThermocable F1124 is a ProReact Plus Digital fixed-temperature linear heat detection cable with a 65°C (149°F) action temperature and a low smoke zero halogen (LSZH) outer coating. The coating is UV stable, flame retardant and resistant to oils and fuels, so the cable can be used indoors or outdoors, and it stays flexible down to -60°C. Like other digital LHD cable it is a twisted pair of tri-metallic conductors in a temperature-sensitive polymer that short together when the action temperature is reached anywhere along the run.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFixed-temperature (digital) linear heat detection cable, action temperature 65°C (149°F)\u003c\/li\u003e\n\u003cli\u003eLow smoke zero halogen (LSZH) outer coating; red\u003c\/li\u003e\n\u003cli\u003eUV stable for indoor and outdoor use; flame retardant; oil and fuel resistant\u003c\/li\u003e\n\u003cli\u003eMaximum ambient temperature 47°C (116°F); minimum operating temperature -60°C (-76°F)\u003c\/li\u003e\n\u003cli\u003ecUL\/UL 521 approved (File S8976); CE marked; RoHS compliant\u003c\/li\u003e\n\u003cli\u003eUp to 3,000 m (10,000 ft) per zone\u003c\/li\u003e\n\u003cli\u003eCompatible with the ProReact Digital Interface Monitor Module and all ProReact LHD accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAction temperature\u003c\/th\u003e\n\u003ctd\u003e65°C (149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum ambient temperature\u003c\/th\u003e\n\u003ctd\u003e47°C (116°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum operating temperature\u003c\/th\u003e\n\u003ctd\u003e-60°C (-76°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter coating\u003c\/th\u003e\n\u003ctd\u003eLSZH (low smoke zero halogen), UV and hydrocarbon resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDiameter\u003c\/th\u003e\n\u003ctd\u003e3.66 mm +\/- 0.12 mm (0.144 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum voltage rating\u003c\/th\u003e\n\u003ctd\u003e30 VAC, 42 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResistance\u003c\/th\u003e\n\u003ctd\u003eApprox. 100 ohms\/km (30.4 ohms\/kft) per leg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum bend radius\u003c\/th\u003e\n\u003ctd\u003e50 mm (2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum zone length\u003c\/th\u003e\n\u003ctd\u003e3,000 m (10,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpool length\u003c\/th\u003e\n\u003ctd\u003e500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatible With\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConventional fire alarm panel initiating device circuits\u003c\/li\u003e\n\u003cli\u003eAddressable loops via a zone\/switch monitor module\u003c\/li\u003e\n\u003cli\u003eThermocable ProReact Digital Interface Monitor Module (A1349)\u003c\/li\u003e\n\u003cli\u003eProReact fixing clips and accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.thermocable.com\/downloads\/48\/ProReact%20Plus%20Digital%20LHD%20Cable%20Installation%20Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProReact Plus Digital LHD Cable Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.thermocable.com\/downloads\/49\/Thermocable%20ProReact%20Plus%20Digital%20LHD%20Cable%202024.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProReact Plus Digital LHD Cable Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.thermocable.com\/downloads\/30\/ProReact%20Accessories%20Guide%202024.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProReact Accessories Guide (Rev 3.1, Feb 2024)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Thermocable","offers":[{"title":"Default Title","offer_id":48201493151968,"sku":"F1124","price":501.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/vesda-fire-alarms-default-title-vesda-vsp-1004-40062244094176_d764f097-e3a7-476f-ad4b-ae86b42047b0.webp?v=1764878906"},{"product_id":"thermocable-f3050","title":"Thermocable F3050 ProReact EN Analogue Linear Heat Detection Cable, PVC Coated","description":"\u003cp\u003e\u003cstrong\u003eThermocable F3050\u003c\/strong\u003e — PVC coated analogue linear heat detection sensor cable for the ProReact EN Analogue system.\u003c\/p\u003e\u003cp\u003eLinear heat detection covers runs where a fire can start anywhere and point detectors cannot see it. Polymers inside the cable drop in resistance as temperature rises; the ProReact EN Analogue Composite Control Unit measures that resistance and the average ambient along the run, giving pre-alarm and alarm from one cable.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFour-core twisted with 100% foil shield; red PVC coat, 4.83 mm (0.190 in) diameter\u003c\/li\u003e\n\u003cli\u003eMinimum bend radius 60 mm (2.36 in); minimum ambient -40 °C\u003c\/li\u003e\n\u003cli\u003eZone length 30 to 50 m minimum by setting, 500 m maximum\u003c\/li\u003e\n\u003cli\u003eAlarm temperature is set at the control unit, not by the cable: Class A1I\/A2I, Class BI, or 54 to 100 °C\u003c\/li\u003e\n\u003cli\u003eVdS EN54-22 approved, certificate G220006; UL 521 listed, file S8976\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eF3051 is the same cable in a nylon jacket, UV stable for sunlight; F3052 adds a steel braid but is VdS approved only, not UL 521 listed. Use only with the A1389 control unit and A1470 end-of-line unit. F3050 covers 100 m, 250 m and 500 m reels under one part number, so confirm reel length.\u003c\/p\u003e","brand":"Thermocable","offers":[{"title":"Default Title","offer_id":48201493184736,"sku":"F3050","price":861.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/vesda-fire-alarms-default-title-vesda-vsp-1004-40062244094176_7f1be545-b748-412c-9aba-e447b587c107.webp?v=1764878909"},{"product_id":"genesis-45071104","title":"Genesis 45071104 18\/4 Solid Unshielded Plenum, FPLP, 1000' (304.8 m) Pull Box, Red","description":"\u003ch2\u003eGenesis 45071104 18\/4 Solid Unshielded Fire Alarm Cable, Plenum, FPLP, 1000' (304.8 m) Pull Box, Red\u003cbr\u003e\n\u003c\/h2\u003e","brand":"Genesis","offers":[{"title":"Default Title","offer_id":53236813267168,"sku":"45071104","price":319.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/WG-45071104.jpg?v=1782679407"},{"product_id":"windy-city-wire-311011-16-awg-stranded-tffn-single-conductor-wire-600v-black-1000-ft","title":"Windy City Wire 311011 16 AWG Stranded TFFN Single Conductor Wire, 600V, Black, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e311011\u003c\/strong\u003e (Windy City Wire catalog number 0311011) is a 16 AWG stranded single-conductor wire with a black nylon jacket, UL listed as Type TFFN and rated 600 V. Windy City Wire describes it as \"16-1C STR TFFN 600V Blk\" and supplies it in 1,000 ft lengths. The spec sheet references NEC Article 402.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer catalog number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0311011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG 1 Conductor Stranded (19 Strand) TFFN 600 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.100\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 lbs\/Mft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(UL) TFFN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrint legend\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 16AWG (UL) TYPE TFFN GASOLINE AND OIL RESISTANT AT 75C 600V MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 402; Made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle conductor: order one length per color required for the circuit.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the 600 V rating or the 90 °C dry \/ 75 °C wet temperature limits.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer references NEC Article 402; confirm that TFFN is permitted for the application with the applicable code and the authority having jurisdiction.\u003c\/li\u003e\n\u003cli\u003eAll values are nominal, per the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_0311011.pdf\"\u003eWindy City Wire spec sheet, Part Number 0311011 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/building-wire\/single-conductor-stranded\/awg\/16\/p\/0311011\"\u003eWindy City Wire product page, 0311011\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from the Windy City Wire spec sheet for Part Number 0311011 and the Windy City Wire product page for 0311011. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753686204640,"sku":"311011","price":238.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/16-1C_STR_TFFN_600V_Blk.png?v=1791291937"},{"product_id":"windy-city-wire-31403-14-awg-stranded-thhn-thwn-single-conductor-wire-600v-yellow-1000-ft","title":"Windy City Wire 31403 14 AWG Stranded THHN\/THWN Single Conductor Wire, 600V, Yellow, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e31403\u003c\/strong\u003e (Windy City Wire catalog number 031403) is a 14 AWG stranded single-conductor building wire with a yellow nylon jacket, rated 600 V. It carries the (UL) Type THHN\/THWN and C(UL) T90 Nylon\/TWN75 markings. Windy City Wire describes it as \"14-1C STR THHN 600V Ylw\" and supplies it in 1,000 ft lengths.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer catalog number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e031403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG 1 Conductor Stranded (19 Strand) THHN 600 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.112\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lbs\/Mft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(UL) THHN\/THWN, C(UL) T90\/TWN75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrint legend\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 14AWG (UL) TYPE THHN OR THWN GRII 600V C(UL) TYPE T90 NYLON OR TWN75 MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 310; Made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle conductor: order one length per color required for the circuit.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the 600 V rating or the 90 °C dry \/ 75 °C wet temperature limits.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer references NEC Article 310; install according to the applicable code and the authority having jurisdiction.\u003c\/li\u003e\n\u003cli\u003eAll values are nominal, per the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_031403.pdf\"\u003eWindy City Wire spec sheet, Part Number 031403 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/building-wire\/single-conductor-stranded\/awg\/14\/p\/031403\"\u003eWindy City Wire product page, 031403\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from the Windy City Wire spec sheet for Part Number 031403 and the Windy City Wire product page for 031403. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753686270176,"sku":"31403","price":238.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/14-1C_STR_THHN_600V_Ylw.png?v=1791291939"},{"product_id":"windy-city-wire-31408-14-awg-stranded-thhn-thwn-single-conductor-wire-600v-pink-1000-ft","title":"Windy City Wire 31408 14 AWG Stranded THHN\/THWN Single Conductor Wire, 600V, Pink, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e31408\u003c\/strong\u003e (Windy City Wire catalog number 031408) is a 14 AWG stranded single-conductor building wire with a pink nylon jacket, rated 600 V. It carries the (UL) Type THHN\/THWN and C(UL) T90 Nylon\/TWN75 markings. Windy City Wire describes it as \"14-1C STR THHN 600V Pnk\" and supplies it in 1,000 ft lengths.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer catalog number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e031408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG 1 Conductor Stranded (19 Strand) THHN 600 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.112\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lbs\/Mft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(UL) THHN\/THWN, C(UL) T90\/TWN75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrint legend\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 14AWG (UL) TYPE THHN OR THWN GRII 600V C(UL) TYPE T90 NYLON OR TWN75 MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 310; Made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle conductor: order one length per color required for the circuit.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the 600 V rating or the 90 °C dry \/ 75 °C wet temperature limits.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer references NEC Article 310; install according to the applicable code and the authority having jurisdiction.\u003c\/li\u003e\n\u003cli\u003eAll values are nominal, per the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_031408.pdf\"\u003eWindy City Wire spec sheet, Part Number 031408 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/building-wire\/single-conductor-stranded\/awg\/14\/p\/031408\"\u003eWindy City Wire product page, 031408\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from the Windy City Wire spec sheet for Part Number 031408 and the Windy City Wire product page for 031408. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753686302944,"sku":"31408","price":238.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/14-1C_STR_THHN_600V_Pnk.png?v=1791291940"},{"product_id":"windy-city-wire-31101-16-awg-stranded-tffn-single-conductor-wire-600v-red-1000-ft","title":"Windy City Wire 31101 16 AWG Stranded TFFN Single Conductor Wire, 600V, Red, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e31101\u003c\/strong\u003e (Windy City Wire catalog number 031101) is a 16 AWG stranded single-conductor wire with a red nylon jacket, UL listed as Type TFFN and rated 600 V. Windy City Wire describes it as \"16-1C STR TFFN 600V Red\" and supplies it in 1,000 ft lengths. The spec sheet references NEC Article 402.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer catalog number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e031101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG 1 Conductor Stranded (19 Strand) TFFN 600 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.100\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 lbs\/Mft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(UL) TFFN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrint legend\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 16AWG (UL) TYPE TFFN GASOLINE AND OIL RESISTANT AT 75C 600V MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 402; Made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle conductor: order one length per color required for the circuit.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the 600 V rating or the 90 °C dry \/ 75 °C wet temperature limits.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer references NEC Article 402; confirm that TFFN is permitted for the application with the applicable code and the authority having jurisdiction.\u003c\/li\u003e\n\u003cli\u003eAll values are nominal, per the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_031101.pdf\"\u003eWindy City Wire spec sheet, Part Number 031101 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/building-wire\/single-conductor-stranded\/awg\/16\/p\/031101\"\u003eWindy City Wire product page, 031101\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from the Windy City Wire spec sheet for Part Number 031101 and the Windy City Wire product page for 031101. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753686466784,"sku":"31101","price":158.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/16-1C_STR_TFFN_600V_Red.png?v=1791291943"},{"product_id":"windy-city-wire-314011-14-awg-stranded-thhn-thwn-single-conductor-wire-600v-black-1000-ft","title":"Windy City Wire 314011 14 AWG Stranded THHN\/THWN Single Conductor Wire, 600V, Black, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e314011\u003c\/strong\u003e (Windy City Wire catalog number 0314011) is a 14 AWG stranded single-conductor building wire with a black nylon jacket, rated 600 V. It carries the (UL) Type THHN\/THWN and C(UL) T90 Nylon\/TWN75 markings. Windy City Wire describes it as \"14-1C STR THHN 600V Blk\" and supplies it in 1,000 ft lengths.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer catalog number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0314011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG 1 Conductor Stranded (19 Strand) THHN 600 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.112\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lbs\/Mft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(UL) THHN\/THWN, C(UL) T90\/TWN75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrint legend\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 14AWG (UL) TYPE THHN OR THWN GRII 600V C(UL) TYPE T90 NYLON OR TWN75 MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 310; Made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle conductor: order one length per color required for the circuit.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the 600 V rating or the 90 °C dry \/ 75 °C wet temperature limits.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer references NEC Article 310; install according to the applicable code and the authority having jurisdiction.\u003c\/li\u003e\n\u003cli\u003eAll values are nominal, per the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_0314011.pdf\"\u003eWindy City Wire spec sheet, Part Number 0314011 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/building-wire\/single-conductor-stranded\/awg\/14\/p\/0314011\"\u003eWindy City Wire product page, 0314011\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from the Windy City Wire spec sheet for Part Number 0314011 and the Windy City Wire product page for 0314011. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753686597856,"sku":"314011","price":238.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/14-1C_STR_THHN_600V_Blk.png?v=1791291947"},{"product_id":"windy-city-wire-314010-14-awg-stranded-thhn-thwn-single-conductor-wire-600v-white-1000-ft","title":"Windy City Wire 314010 14 AWG Stranded THHN\/THWN Single Conductor Wire, 600V, White, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e314010\u003c\/strong\u003e (Windy City Wire catalog number 0314010) is a 14 AWG stranded single-conductor building wire with a white nylon jacket, rated 600 V. It carries the (UL) Type THHN\/THWN and C(UL) T90 Nylon\/TWN75 markings. Windy City Wire describes it as \"14-1C STR THHN 600V Wht\" and supplies it in 1,000 ft lengths.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer catalog number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0314010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG 1 Conductor Stranded (19 Strand) THHN 600 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.112\" nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lbs\/Mft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(UL) THHN\/THWN, C(UL) T90\/TWN75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrint legend\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 14AWG (UL) TYPE THHN OR THWN GRII 600V C(UL) TYPE T90 NYLON OR TWN75 MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 310; Made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle conductor: order one length per color required for the circuit.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the 600 V rating or the 90 °C dry \/ 75 °C wet temperature limits.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer references NEC Article 310; install according to the applicable code and the authority having jurisdiction.\u003c\/li\u003e\n\u003cli\u003eAll values are nominal, per the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_0314010.pdf\"\u003eWindy City Wire spec sheet, Part Number 0314010 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/building-wire\/single-conductor-stranded\/awg\/14\/p\/0314010\"\u003eWindy City Wire product page, 0314010\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from the Windy City Wire spec sheet for Part Number 0314010 and the Windy City Wire product page for 0314010. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753687023840,"sku":"314010","price":238.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/14-1C_STR_THHN_600V_Wht.png?v=1791291950"},{"product_id":"windy-city-wire-31404-031404-14-awg-1-conductor-stranded-thhn-600v-wire-orange-jacket-1000","title":"Windy City Wire 31404 (031404) 14 AWG 1 Conductor Stranded THHN 600V Wire, Orange Jacket, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e31404\u003c\/strong\u003e is Windy City Wire catalog number 031404, a 14 AWG single conductor stranded THHN\/THWN building wire with a orange nylon jacket, rated 600 V. It carries UL Type THHN\/THWN and C(UL) T90\/TWN75 ratings and falls under NEC Article 310. The orange jacket supports color-coded control, signaling and power circuits pulled through conduit and raceways.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31404 (Windy City Wire 031404)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG 1 conductor stranded (19 strand) THHN, 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlenum rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-plenum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.112 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lb per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 310; UL THHN\/THWN; C(UL) T90\/TWN75; made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 14AWG (UL) TYPE THHN OR THWN GRII 600V C(UL) TYPE T90 NYLON OR TWN75 MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTHHN\/THWN single conductor building wire installed under NEC Article 310; follow local code and the authority having jurisdiction for the circuit type.\u003c\/li\u003e\n\u003cli\u003eNon-plenum cable: do not run it exposed in plenum air-handling spaces.\u003c\/li\u003e\n\u003cli\u003eTemperature rating is 90 °C in dry locations and 75 °C in wet locations.\u003c\/li\u003e\n\u003cli\u003ePart of the Windy City Wire SmartWire line, with FastFIND footage markers printed on the jacket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindy City Wire 031404-CT, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003cli\u003eWindy City Wire 031404-SI, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003cli\u003eWindy City Wire 1401THHN-STR-ORG, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_031404.pdf\"\u003eWindy City Wire spec sheet, 031404 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/wire\/p\/031404\"\u003eWindy City Wire product page, 031404\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Windy City Wire spec sheet, part number 031404. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753687122144,"sku":"31404","price":238.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/14-1C_STR_THHN_600V_Org.png?v=1791291953"},{"product_id":"windy-city-wire-31409-031409-14-awg-1-conductor-stranded-thhn-600v-wire-blue-jacket-1000-f","title":"Windy City Wire 31409 (031409) 14 AWG 1 Conductor Stranded THHN 600V Wire, Blue Jacket, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e31409\u003c\/strong\u003e is Windy City Wire catalog number 031409, a 14 AWG single conductor stranded THHN\/THWN building wire with a blue nylon jacket, rated 600 V. It carries UL Type THHN\/THWN and C(UL) T90\/TWN75 ratings and falls under NEC Article 310. The blue jacket supports color-coded control, signaling and power circuits pulled through conduit and raceways.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31409 (Windy City Wire 031409)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG 1 conductor stranded (19 strand) THHN, 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlenum rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-plenum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.112 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lb per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 310; UL THHN\/THWN; C(UL) T90\/TWN75; made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 14AWG (UL) TYPE THHN OR THWN GRII 600V C(UL) TYPE T90 NYLON OR TWN75 MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTHHN\/THWN single conductor building wire installed under NEC Article 310; follow local code and the authority having jurisdiction for the circuit type.\u003c\/li\u003e\n\u003cli\u003eNon-plenum cable: do not run it exposed in plenum air-handling spaces.\u003c\/li\u003e\n\u003cli\u003eTemperature rating is 90 °C in dry locations and 75 °C in wet locations.\u003c\/li\u003e\n\u003cli\u003ePart of the Windy City Wire SmartWire line, with FastFIND footage markers printed on the jacket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_031409.pdf\"\u003eWindy City Wire spec sheet, 031409 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/wire\/p\/031409\"\u003eWindy City Wire product page, 031409\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Windy City Wire spec sheet, part number 031409. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753687154912,"sku":"31409","price":238.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/14-1C_STR_THHN_600V_Blu.png?v=1791291953"},{"product_id":"windy-city-wire-31105-031105-16-awg-1-conductor-stranded-tffn-600v-wire-purple-jacket-1000","title":"Windy City Wire 31105 (031105) 16 AWG 1 Conductor Stranded TFFN 600V Wire, Purple Jacket, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e31105\u003c\/strong\u003e is Windy City Wire catalog number 031105, a 16 AWG single conductor stranded TFFN fixture wire with a purple jacket, rated 600 V. It is UL listed Type TFFN, marked gasoline and oil resistant at 75 °C, and falls under NEC Article 402. The purple jacket helps identify individual conductors in control and signaling wiring.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31105 (Windy City Wire 031105)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG 1 conductor stranded (19 strand) TFFN, 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePurple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlenum rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-plenum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.100 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 lb per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 402; UL TFFN; made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 16AWG (UL) TYPE TFFN GASOLINE AND OIL RESISTANT AT 75C 600V MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTFFN fixture wire installed under NEC Article 402; follow local code and the authority having jurisdiction for the circuit type.\u003c\/li\u003e\n\u003cli\u003eNon-plenum cable: do not run it exposed in plenum air-handling spaces.\u003c\/li\u003e\n\u003cli\u003eTemperature rating is 90 °C in dry locations and 75 °C in wet locations; marked gasoline and oil resistant at 75 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_031105.pdf\"\u003eWindy City Wire spec sheet, 031105 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/wire\/p\/031105\"\u003eWindy City Wire product page, 031105\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Windy City Wire spec sheet, part number 031105. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753687253216,"sku":"31105","price":158.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/16-1C_STR_TFFN_600V_Pur.png?v=1791291957"},{"product_id":"windy-city-wire-31405-si-031405-si-14-awg-1-conductor-stranded-thhn-600v-wire-purple-jacke","title":"Windy City Wire 31405-SI (031405-SI) 14 AWG 1 Conductor Stranded THHN 600V Wire, Purple Jacket, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e31405-SI\u003c\/strong\u003e is Windy City Wire catalog number 031405-SI, a 14 AWG single conductor stranded THHN\/THWN building wire with a purple nylon jacket, rated 600 V. It carries UL Type THHN\/THWN and C(UL) T90\/TWN75 ratings and falls under NEC Article 310. The purple jacket supports color-coded control, signaling and power circuits pulled through conduit and raceways.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31405-SI (Windy City Wire 031405-SI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG 1 conductor stranded (19 strand) THHN, 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePurple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlenum rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-plenum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.112 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lb per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 310; UL THHN\/THWN; C(UL) T90\/TWN75; made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 14AWG (UL) TYPE THHN OR THWN GRII 600V C(UL) TYPE T90 NYLON OR TWN75 MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTHHN\/THWN single conductor building wire installed under NEC Article 310; follow local code and the authority having jurisdiction for the circuit type.\u003c\/li\u003e\n\u003cli\u003eNon-plenum cable: do not run it exposed in plenum air-handling spaces.\u003c\/li\u003e\n\u003cli\u003eTemperature rating is 90 °C in dry locations and 75 °C in wet locations.\u003c\/li\u003e\n\u003cli\u003ePart of the Windy City Wire SmartWire line, with FastFIND footage markers printed on the jacket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindy City Wire 031405-CT, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003cli\u003eWindy City Wire 1401THHN-STR-PUR, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_031405-SI.pdf\"\u003eWindy City Wire spec sheet, 031405-SI (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/wire\/p\/031405-SI\"\u003eWindy City Wire product page, 031405-SI\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Windy City Wire spec sheet, part number 031405-SI. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753687711968,"sku":"31405-SI","price":227.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/14-1C_STR_THHN_600V_Pur.png?v=1791291959"},{"product_id":"windy-city-wire-314012-0314012-14-awg-1-conductor-stranded-thhn-600v-wire-brown-jacket-100","title":"Windy City Wire 314012 (0314012) 14 AWG 1 Conductor Stranded THHN 600V Wire, Brown Jacket, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e314012\u003c\/strong\u003e is Windy City Wire catalog number 0314012, a 14 AWG single conductor stranded THHN\/THWN building wire with a brown nylon jacket, rated 600 V. It carries UL Type THHN\/THWN and C(UL) T90\/TWN75 ratings and falls under NEC Article 310. The brown jacket supports color-coded control, signaling and power circuits pulled through conduit and raceways.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e314012 (Windy City Wire 0314012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG 1 conductor stranded (19 strand) THHN, 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlenum rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-plenum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.112 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lb per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 310; UL THHN\/THWN; C(UL) T90\/TWN75; made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 14AWG (UL) TYPE THHN OR THWN GRII 600V C(UL) TYPE T90 NYLON OR TWN75 MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTHHN\/THWN single conductor building wire installed under NEC Article 310; follow local code and the authority having jurisdiction for the circuit type.\u003c\/li\u003e\n\u003cli\u003eNon-plenum cable: do not run it exposed in plenum air-handling spaces.\u003c\/li\u003e\n\u003cli\u003eTemperature rating is 90 °C in dry locations and 75 °C in wet locations.\u003c\/li\u003e\n\u003cli\u003ePart of the Windy City Wire SmartWire line, with FastFIND footage markers printed on the jacket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindy City Wire 0314012-CT, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003cli\u003eWindy City Wire 0314012-SI, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003cli\u003eWindy City Wire 1401THHN-STR-BRN, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_0314012.pdf\"\u003eWindy City Wire spec sheet, 0314012 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/wire\/p\/0314012\"\u003eWindy City Wire product page, 0314012\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Windy City Wire spec sheet, part number 0314012. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753687777504,"sku":"314012","price":238.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/14-1C_STR_THHN_600V_Brn.png?v=1791291959"},{"product_id":"windy-city-wire-31407-031407-14-awg-1-conductor-stranded-thhn-600v-wire-gray-jacket-1000-f","title":"Windy City Wire 31407 (031407) 14 AWG 1 Conductor Stranded THHN 600V Wire, Gray Jacket, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e31407\u003c\/strong\u003e is Windy City Wire catalog number 031407, a 14 AWG single conductor stranded THHN\/THWN building wire with a gray nylon jacket, rated 600 V. It carries UL Type THHN\/THWN and C(UL) T90\/TWN75 ratings and falls under NEC Article 310. The gray jacket supports color-coded control, signaling and power circuits pulled through conduit and raceways.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31407 (Windy City Wire 031407)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG 1 conductor stranded (19 strand) THHN, 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlenum rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-plenum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.112 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lb per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 310; UL THHN\/THWN; C(UL) T90\/TWN75; made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 14AWG (UL) TYPE THHN OR THWN GRII 600V C(UL) TYPE T90 NYLON OR TWN75 MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTHHN\/THWN single conductor building wire installed under NEC Article 310; follow local code and the authority having jurisdiction for the circuit type.\u003c\/li\u003e\n\u003cli\u003eNon-plenum cable: do not run it exposed in plenum air-handling spaces.\u003c\/li\u003e\n\u003cli\u003eTemperature rating is 90 °C in dry locations and 75 °C in wet locations.\u003c\/li\u003e\n\u003cli\u003ePart of the Windy City Wire SmartWire line, with FastFIND footage markers printed on the jacket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindy City Wire 1401THHN-STR-GRY, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_031407.pdf\"\u003eWindy City Wire spec sheet, 031407 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/wire\/p\/031407\"\u003eWindy City Wire product page, 031407\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Windy City Wire spec sheet, part number 031407. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753687908576,"sku":"31407","price":238.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/14-1C_STR_THHN_600V_Gry.png?v=1791291963"},{"product_id":"windy-city-wire-311018-0311018-16-awg-1-conductor-stranded-tffn-600v-wire-pink-jacket-1000","title":"Windy City Wire 311018 (0311018) 16 AWG 1 Conductor Stranded TFFN 600V Wire, Pink Jacket, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e311018\u003c\/strong\u003e is Windy City Wire catalog number 0311018, a 16 AWG single conductor stranded TFFN fixture wire with a pink jacket, rated 600 V. It is a 19 strand, unshielded, non-plenum conductor. The pink jacket helps identify individual conductors in control and signaling wiring.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e311018 (Windy City Wire 0311018)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG 1 conductor stranded (19 strand) TFFN, 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 AWG, 1 conductor, 19 strand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlenum rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-plenum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 lb per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTFFN fixture wire; follow local code and the authority having jurisdiction for the circuit type.\u003c\/li\u003e\n\u003cli\u003eNon-plenum cable: do not run it exposed in plenum air-handling spaces.\u003c\/li\u003e\n\u003cli\u003eWindy City Wire does not publish a spec sheet for this color; confirm insulation thickness, diameter, marking and listings with the manufacturer if the project specification requires them.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/wire\/p\/0311018\"\u003eWindy City Wire product page, 0311018\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Windy City Wire product page, part number 0311018. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753688334560,"sku":"311018","price":162.9,"currency_code":"USD","in_stock":true}]},{"product_id":"windy-city-wire-31401-031401-14-awg-1-conductor-stranded-thhn-600v-wire-red-jacket-1000-ft","title":"Windy City Wire 31401 (031401) 14 AWG 1 Conductor Stranded THHN 600V Wire, Red Jacket, 1000 ft","description":"\u003cp\u003e\u003cstrong\u003e31401\u003c\/strong\u003e is Windy City Wire catalog number 031401, a 14 AWG single conductor stranded THHN\/THWN building wire with a red nylon jacket, rated 600 V. It carries UL Type THHN\/THWN and C(UL) T90\/TWN75 ratings and falls under NEC Article 310. The red jacket supports color-coded control, signaling and power circuits pulled through conduit and raceways.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31401 (Windy City Wire 031401)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG 1 conductor stranded (19 strand) THHN, 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG, 19 strand bare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, .015 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNylon, .004 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlenum rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-plenum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.112 in. nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lb per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 °C dry, 75 °C wet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEC Article 310; UL THHN\/THWN; C(UL) T90\/TWN75; made in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWINDY CITY WIRE 14AWG (UL) TYPE THHN OR THWN GRII 600V C(UL) TYPE T90 NYLON OR TWN75 MADE IN THE USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePut-up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTHHN\/THWN single conductor building wire installed under NEC Article 310; follow local code and the authority having jurisdiction for the circuit type.\u003c\/li\u003e\n\u003cli\u003eNon-plenum cable: do not run it exposed in plenum air-handling spaces.\u003c\/li\u003e\n\u003cli\u003eTemperature rating is 90 °C in dry locations and 75 °C in wet locations.\u003c\/li\u003e\n\u003cli\u003ePart of the Windy City Wire SmartWire line, with FastFIND footage markers printed on the jacket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindy City Wire 031401-CT, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003cli\u003eWindy City Wire 031401-SI, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003cli\u003eWindy City Wire 1401THHN-STR-RED, listed by Windy City Wire as an equal part number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/harrier.smartwire.com\/ecom\/specdisplay.php\/wcw_031401.pdf\"\u003eWindy City Wire spec sheet, 031401 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/windycitywire.com\/products\/wire\/p\/031401\"\u003eWindy City Wire product page, 031401\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Windy City Wire spec sheet, part number 031401. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Windy City Wire","offers":[{"title":"Default Title","offer_id":67753688400096,"sku":"31401","price":238.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/14-1C_STR_THHN_600V_Red.png?v=1791291966"}],"url":"https:\/\/thefirealarmsupplier.com\/collections\/wires.oembed?page=2","provider":"The Fire Alarm Supplier","version":"1.0","type":"link"}