{"title":"Fire Alarm Control Panels","description":"\u003cp\u003eThe fire alarm control panel is the head end of the system. It supervises every initiating device and notification circuit, processes alarm, supervisory and trouble conditions, and drives evacuation signalling and off-premises reporting. Everything else on the job wires back to it.\u003c\/p\u003e\n\u003cp\u003ePanels divide broadly into conventional systems, where devices are grouped onto zoned initiating circuits, and addressable systems, where each device carries a point address on a signalling line circuit and reports its own status individually. An addressable fire alarm panel makes locating a device and spotting a dirty detector far quicker, while conventional panels remain common in smaller buildings and retrofit work. Alongside the main panel you will also find releasing panels for suppression, voice evacuation equipment, and the expansion boards, SLC loop cards, power supplies and NAC extenders that go with them.\u003c\/p\u003e\n\u003cp\u003eWe carry fire alarm control panels from Notifier, Fire-Lite, Simplex, Silent Knight, Farenhyt, Gamewell-FCI, Edwards, Kidde, Napco and Potter, current stock plus discontinued panels and boards for systems that are not due for replacement yet. Ask about hard to find panels through our \u003ca href=\"\/pages\/request-a-quote\"\u003equote page\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"simplex-4010-9401-addressable-fire-control-unit-120v","title":"Simplex 4010-9401 4010ES Addressable Fire Alarm Control Unit, 250-Point IDNet2, Red, 120 VAC","description":"\u003cp\u003e\u003cstrong\u003eSimplex 4010-9401\u003c\/strong\u003e — 4010ES basic addressable fire alarm control unit, red one-bay cabinet, 2x40 character LCD interface, 120 VAC supply.\u003c\/p\u003e\u003cp\u003eThe 4010ES is the compact member of the Simplex ES family, for buildings needing TrueAlarm analog addressable detection without a 4100ES cabinet. It ships as a basic unit — master controller with Compact Flash, Main System Supply 2 and one addressable channel — with three 4 in. × 5 in. block spaces free for option cards.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOne two-loop isolated IDNet2 channel, Class A or B, up to 250 addressable IDNet points\u003c\/li\u003e\n\u003cli\u003eFour Class A or B NACs rated 3 A each, selectable for synchronized strobe or SmartSync\u003c\/li\u003e\n\u003cli\u003e8 A supply with up to 2 A auxiliary; programmable relay rated 2 A at 32 VDC\u003c\/li\u003e\n\u003cli\u003eBattery charger to 110 Ah (UL) or 50 Ah (ULC); 33 Ah max in the one-bay cabinet\u003c\/li\u003e\n\u003cli\u003e316 mA supervisory, 430 mA alarm; uses 2 of the 20 card addresses\u003c\/li\u003e\n\u003cli\u003eUL and FM listed; NEMA 1 and IP 30 cabinet with an RUI port\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eCheck the suffix: 4010-9402 is platinum, 4010-9501 red at 220–240 VAC, 4010-9404 adds 48 LED annunciation, and 4010-9505 substitutes an ESMX loop channel.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":43132797747424,"sku":"4010-9401","price":2325.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/simplex-control-panels-default-title-simplex-4010-9401-addressable-fire-control-unit-120v-31897041469664.jpg?v=1763279445"},{"product_id":"silent-knight-6820-1110-point-addressable-facp","title":"Silent Knight 6820 1110-Point Addressable FACP","description":"\u003cp\u003e\u003cstrong\u003e6820\u003c\/strong\u003e — intelligent addressable fire alarm control panel with a built-in dual-technology (IP and POTS) communicator, expandable to 1,110 SK points.\u003c\/p\u003e\u003cp\u003eThe 6820 is the latest intelligent addressable FACP from Silent Knight and is a direct replacement for the 5820XL. The panel has one built-in signaling line circuit, which can support 159 System Sensor SK detectors and 159 SK modules, or 127 Hochiki SD protocol devices; additional SLC loops can be added for a maximum of 1,110 (SK) or 635 (SD) points per panel. Six onboard Flexput circuits can each be configured as a notification output or as auxiliary power, and the panel adds a form-C trouble relay plus two programmable form-C relays. Software features include drift compensation, pre-trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and a calibration trouble alert. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable, with a designated panel configured as the communicator for all panels in the link.\u003c\/p\u003e\u003cp\u003eThe built-in digital alarm communicator\/transmitter is dual technology. The POTS side transmits system status to a central station over the public switched telephone network, while the IP communicator sends alarm signals over the Internet, saving the monthly cost of two dedicated business telephone lines. The secondary telephone line may be retained as backup although it is not required, and optional cellular reporting is available.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent signaling line circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 (expandable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable device capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,110 (SK) or 635 (SD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevices per built-in SLC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e159 SK detectors and 159 SK modules, or 127 SD protocol devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 (expandable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSBUS devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 (16 annunciators, 8 LED modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz, 3.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlexput circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block provides connections for six Class B or three Class A NACs or auxiliary power; power-limited, supervised circuitry. Maximum current per circuit 3 A, and cannot exceed 6 A total for all circuits. End-of-line resistor 4.7k ohm, ½ watt for Class B NACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupervised and power-limited, Class A or Class B, 32 VDC, 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay contact rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A @ 27.4 VDC (resistive), Form C — two programmable relays and one fixed trouble relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCabinet holds a maximum of two 18 AH batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery charger capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 to 35 AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.4\" W x 26.4\" H x 4.1\" D (41.66 cm x 67.06 cm x 10.41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 lbs. (14.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets NFPA requirements for operation at 0 to 49°C (32 to 120°F) and 93% ± 2% RH non-condensing at 32°C ± 2°C (90°F ± 3°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 864 10th Edition and UL 2572 2nd Edition; complies with NFPA 72, NFPA 13, NFPA 15, NFPA 16, NFPA 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed S2766; CSFM 7165-0559:0500; FDNY COA# 6249; FM Approved; Seismic (CA) VMA-45894-05C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe 6 A Flexput cap is a total, not a per-circuit figure:\u003c\/strong\u003e each of the six Flexput circuits is rated 3 A maximum, but all circuits together cannot exceed 6 A. Sizing six circuits at 3 A each will overload the supply — budget the notification load against the 6 A ceiling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass A halves the circuit count:\u003c\/strong\u003e the same terminal block yields either six Class B NACs or three Class A NACs. Decide the survivability class before laying out notification zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSK and SD devices cannot be mixed:\u003c\/strong\u003e the panel speaks both System Sensor (SK) and Hochiki (SD) protocol, but the two device families cannot be mixed in the same fire alarm system, and the point ceiling differs sharply — 1,110 for SK against 635 for SD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd-of-line resistor:\u003c\/strong\u003e 4.7k ohm, ½ watt on Class B NAC circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity is split between two limits:\u003c\/strong\u003e the charger handles 7 to 35 AH, but the panel cabinet only holds up to two 18 AH batteries. Anything larger requires the RBB remote battery box, which holds batteries up to 35 AH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended ambient is narrower than the listed range:\u003c\/strong\u003e although the system meets NFPA requirements to 120°F, Honeywell recommends installing the panel and its peripherals in a normal room temperature of 15 to 27°C (60 to 80°F), because extreme temperature and humidity shorten the useful life of the standby batteries and electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSWIFT wireless is SK-only:\u003c\/strong\u003e SWIFT wireless devices are compatible with System Sensor (SK) devices only and are not compatible with Hochiki (SD) devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e JumpStart auto programming minimizes the work to start a new system; a built-in USB interface, the onboard keypad, remote annunciators, or the Windows-based Honeywell Fire Software Suite (HFSS) can all be used.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRelated models\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6820EVS\u003c\/strong\u003e — the same addressable platform with an integrated emergency voice system added\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5820XL\u003c\/strong\u003e — the previous-generation panel the 6820 directly replaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6815\u003c\/strong\u003e — SLC expander for SK devices; \u003cstrong\u003e5815XL\u003c\/strong\u003e — SLC expander for SD devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5895XL\u003c\/strong\u003e — 6 A power supply with six Flexput circuits and two Form C relays\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5496\u003c\/strong\u003e — 6 amp NAC power expander with four power-limited output circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6860 \/ 6855 \/ 5860 \/ 5860R\u003c\/strong\u003e — LCD remote fire annunciators; \u003cstrong\u003e5865-3\u003c\/strong\u003e and \u003cstrong\u003e5865-4\u003c\/strong\u003e LED annunciators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCELL-CAB-SK \/ CELL-MOD \/ IPGSM-4G\u003c\/strong\u003e — optional cellular and dual-path communicators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSK-NIC\u003c\/strong\u003e — network interface card, with SK-FML (multi-mode) or SK-FSL (single-mode) fiber optic transmitter\/receiver\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRBB\u003c\/strong\u003e — remote battery box accessory cabinet, holds batteries up to 35 AH\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eSpecifications taken from the Honeywell Silent Knight data sheet \"6820 Intelligent Fire Alarm Control Panel with Communicator,\" document 351610:C (2022). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Silent Knight","offers":[{"title":"Default Title","offer_id":43132797780192,"sku":"6820","price":1935.25,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/silent-knight-control-panels-default-title-silent-knight-6820-1110-point-addressable-facp-31896996937952.jpg?v=1763279436"},{"product_id":"simplex-4007-9102-fire-alarm-control-panel","title":"Simplex 4007-9102 4007ES Hybrid Fire Alarm Control Panel, Platinum Cabinet","description":"\u003cp\u003e\u003cstrong\u003eSimplex 4007-9102\u003c\/strong\u003e — a complete 4007ES Hybrid fire detection and control unit in a platinum cabinet.\u003c\/p\u003e\u003cp\u003ePlatinum is the cabinet colour and nothing more: Simplex lists 4007-9101 in red and 4007-9102 in platinum against one shared description. Hybrid means the unit takes addressable and conventional initiation together, which suits retrofits where two-wire zones stay in place.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOne isolated IDNet 2 SLC for 100 addressable points, expandable to 250 with two 4007-9803 modules\u003c\/li\u003e\n\u003cli\u003eOne 8-point zone\/relay module included and three more accepted, each point an IDC or a 2 A relay\u003c\/li\u003e\n\u003cli\u003eFour Class A or Class B NACs at 3 A each for Special Application appliances, within 6 A total\u003c\/li\u003e\n\u003cli\u003e4.3 in. colour touchscreen, 1000 alarm and 1000 trouble log entries, USB and Ethernet\u003c\/li\u003e\n\u003cli\u003eCharges 6.2 to 18 Ah in the cabinet, 33 Ah in an external 4009-9801\u003c\/li\u003e\n\u003cli\u003eCabinet rated NEMA 1 and IP30; listed to UL 864, UL 2017, ULC-S527, ULC-S559\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eCabinet, power supply and one zone\/relay card are included; the two 12 V batteries and the 2975-9813 platinum trim are separate. 4007-9101 is the identical unit in red, and a BA suffix means assembled in the USA.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":43132797845728,"sku":"4007-9102","price":1450.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/simplex-control-panels-default-title-simplex-4007-9102-fire-alarm-control-panel-31897028559072.jpg?v=1763279447"},{"product_id":"fire-lite-es-200x-addressable-fire-control-panel-198-point","title":"Fire-Lite ES-200X Addressable Fire Alarm Control Panel 198 Point","description":"\u003cp\u003e\u003cstrong\u003eES-200X\u003c\/strong\u003e — intelligent addressable fire alarm control panel with one signaling line circuit, 198-point capacity and a pre-installed IPOTS-COM dual-technology (IP and POTS) central station communicator.\u003c\/p\u003e\n\u003cp\u003eThe ES-200X is a direct replacement for the MS-9200UDLS and programs just like Fire•Lite’s other addressable products, yet fits into applications previously served only by conventional panels. Its single SLC (DCL) loop carries up to 198 addressable devices — 99 detectors and 99 modules — meets NFPA Class B and Class A requirements, and runs up to 10,000 ft. (3,000 m) in LiteSpeed mode over twisted, unshielded wire. Four independently programmable NAC output circuits can each be configured Class A or Class B, with selectable strobe synchronization per NAC for System Sensor, Wheelock and Gentex appliances. The panel supports automated activation of the ECC-50\/100 Emergency Command Center and the ECC-FFT firefighter telephone option, and is certified for seismic applications when used with the appropriate seismic mounting kit. The ES-200X ships as the main circuit board with display, pre-installed communicator, chassis with transformer, backbox with door, and a plastic bag containing screws, cables and key.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent signaling line circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; meets NFPA Class B and Class A requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable device capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e198 (99 addressable detectors and 99 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnnunciators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (up to 8 per ANN-BUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiteSpeed and CLIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC wire run\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 ft. (3,000 m) in LiteSpeed mode, twisted unshielded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification appliance circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block provides connections for four NACs, Class B or Class A; special application power; power-limited, supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum signaling current per NAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A special application; 250 mA regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal 24 VDC system power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 A maximum, shared between all NAC circuits and the ANN-BUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC end-of-line resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7k ohm, ½ watt (P\/N 71252 UL listed) for Class B NAC; system capable of 1.9k–22k ohm ELR range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo programmable Form-C relays and one fixed trouble relay; 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive); non-power-limited, non-supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 or 240 VAC, 50\/60 Hz, 3.25 A, auto-sensing (no switch required); minimum 14 AWG (2.00 mm²) with 600 V insulation; non-power-limited, supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 12 V 18 AH lead-acid; charger capacity 7–18 AH; cabinet holds a maximum of two 18 AH batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral 80-character LCD with backlighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackbox\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.00\" (48.26 cm) H × 16.65\" (42.29 cm) W × 5.25\" (13.34 cm) D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.26\" (48.92 cm) H × 16.82\" (42.73 cm) W × 0.72\" (1.82 cm) D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.9 lbs. (12.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–49°C \/ 32–120°F, relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eListed to UL Standard 864, 10th edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeismic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIBC 2021, IBC 2018, IBC 2015, IBC 2012, IBC 2009; CBC 2019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency listings (ES-200X)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL: S624; FM approved; CSFM 7165-0075:0500; FDNY COA #2023-TMCOAP-001919-RENL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower budget:\u003c\/strong\u003e 2.5 A is the per-circuit maximum. Maximum or total 24 VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A — four circuits do not give you four times 2.5 A. Add the PWRMOD24 power expander module to increase alarm power output to 6 amps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDress panel:\u003c\/strong\u003e the ES-200X carton does not list a dress panel (the ES-200XC, ES-200XI and ES-200XP do). Order DP-ES-R separately; TR-CE is the trim ring for semi-flush mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e the cabinet holds a maximum of two 18 AH batteries and the onboard charger covers 7–18 AH. Batteries larger than 18 AH require a CHG-75 or CHG-120F and an external BB-26 or BB-55F enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeismic installations:\u003c\/strong\u003e use SEISKIT-COMMENC, the seismic kit for the ES-200X Series backbox, which includes a battery bracket for two 7, 12 or 18 AH batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy devices:\u003c\/strong\u003e 300 Series devices such as CP300\/CP350, SD300(T)\/SD350(T), M300, M301, M302, C304 and BG-10LX are not compatible with LiteSpeed polling; if any are on the SLC, polling must be set to standard CLIP protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e databases upload and download through the panel USB port, or over ethernet using the IPOTS-COM. Offline programming with FS-Tools requires an ethernet connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-200XC\u003c\/strong\u003e — same panel and pre-installed IPOTS-COM, with a dress panel included in the carton.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-200XI\u003c\/strong\u003e — no communicator fitted; dress panel included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-200XP\u003c\/strong\u003e — integrated CLSS Pathway Pro dual-SIM (AT\u0026amp;T\/Verizon) 5G LTE-M communicator in place of the IPOTS-COM; adds ETL 5017286 and CSFM 7165-0075:0511.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMS-9200UDLS\u003c\/strong\u003e — the legacy panel the ES-200X Series directly replaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the Fire•Lite Alarms data sheet \"ES-200X Series Intelligent Addressable Fire Alarm Control Panels,\" document DF-60957:F (5\/28\/2025). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":43132798042336,"sku":"ES-200X","price":1310.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/fire-lite-control-panels-default-title-fire-lite-es-200x-addressable-fire-control-panel-198-point-31896797839584.jpg?v=1763279458"},{"product_id":"fire-lite-ms-4-fire-alarm-control-panel-4-zone","title":"Fire-Lite MS-4 Fire Alarm Control Panel 4-Zone","description":"\u003cp\u003e\u003cstrong\u003eMS-4\u003c\/strong\u003e — four-zone conventional fire alarm control panel providing reliable fire signaling protection for small to medium sized commercial, industrial and institutional buildings.\u003c\/p\u003e\n\u003cp\u003eThe MS-4 is compatible with System Sensor i3 detectors, microprocessor-based conventional smoke detectors that transmit a maintenance trouble signal indicating the need for cleaning and a supervisory freeze signal when ambient temperature falls below the detector rating. It also accepts conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Four Style B initiating device circuits are provided, one of which is programmable for combination supervisory and waterflow, and each zone carries its own Fire Alarm, Supervisory, Trouble and Maintenance LED plus a front-panel Zone Enable\/Disable button. Outputs include two Style Y notification appliance circuits, Form-C alarm, trouble and supervisory relays, and both resettable and nonresettable 24 VDC special application power. The panel supervises wiring, AC voltage and battery level, and offers a walktest mode from the front keypad.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitiating device circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour IDCs, all Style B (Class B); one zone programmable for combination supervisory and waterflow; power-limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDC operating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 20 VDC, maximum 27 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDC alarm current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDC short circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDC maximum loop resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDC standby current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification appliance circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo NACs, Style Y (Class B), power-limited; nominal 24 VDC, maximum 27 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum signaling current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 amps total with the standard transformer; 5.0 amps total with the optional second transformer (2.5 amp special application, 250 mA regulated maximum per NAC), MS-4 only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC maximum line impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 volt drop end-of-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnd-of-line resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7K, 1\/2 watt (Part #71252) for both IDCs and NACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal system current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 amps standard; 6.0 amps available with the optional second transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm-C relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm relay, fail-safe trouble relay, and supervisory relay (supervisory is MS-4 only); contacts rated 2.0 amps @ 30 VDC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResettable special application power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC, 500 mA maximum, power-limited — appropriate for powering 4-wire smoke detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonresettable special application power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC, 500 mA maximum, power-limited (MS-4 only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 2.3 A (the MS-4E allows connection to 220\/240 VAC, 1.15 A); supervised, nonpower-limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransformer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne 100 VA transformer standard; an optional second 100 VA transformer is available for the MS-4 to provide maximum accessory power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 volt battery charger for batteries up to 18 Amp Hour; cabinet provides space for two 7 Amp Hour batteries; batteries ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackbox\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.5\" (36.8 cm) × 15.218\" (38.65 cm) × 2.875\" (7.3 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePiezo sounder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDistinct patterns for alarm (steady), trouble (1 s on \/ 1 s off), maintenance and supervisory (½ s on \/ ½ s off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl buttons\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcknowledge, Alarm Silence, Reset, Walktest, plus Zone Enable\/Disable per zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass A needs the CAC-4:\u003c\/strong\u003e the IDCs ship as Style B (Class B) and the NACs as Style Y (Class B). The CAC-4 Class A Converter Module — MS-4 only — converts the IDCs to Style D (Class A) and the NACs to Style Z (Class A). It connects to J1 on the MS-4 main circuit board. Class A is not available out of the box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5.0 A NAC output requires the second transformer:\u003c\/strong\u003e with the standard transformer the two NACs share 2.5 amps total. The optional second 100 VA transformer is what raises the panel to 5.0 amps of signaling current and 6.0 amps total system current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWatch the combined budget:\u003c\/strong\u003e total current for nonresettable power, resettable power and the two notification appliance circuits must not exceed 6.0 amps for the MS-4, and that figure itself requires the optional second transformer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery sizing:\u003c\/strong\u003e the charger handles up to 18 Amp Hour, but the cabinet only has room for two 7 Amp Hour batteries. Anything larger requires a UL listed battery box such as the BB-17F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround fault detection:\u003c\/strong\u003e jumper JP3 disables ground fault detection and should only be cut with the approval of the Authority Having Jurisdiction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption module slots:\u003c\/strong\u003e the MS-4 has two sets of option module connectors (J3 \u0026amp; J5 and J4 \u0026amp; J6); the 4XTMF occupies one set. Cut JP1 to supervise a module on J3 \u0026amp; J5, JP2 for J4 \u0026amp; J6.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMS-2\u003c\/strong\u003e — two-zone version with two IDCs and a single NAC; no supervisory relay and no nonresettable power output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMS-4E\u003c\/strong\u003e — same features as the MS-4 but allows connection to 220\/240 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAC-4\u003c\/strong\u003e — Class A converter module, MS-4 only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4XTMF\u003c\/strong\u003e — transmitter module providing a supervised output for a local energy municipal box transmitter plus alarm and trouble reverse polarity, with disable switch and disable trouble LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDP-MS2\/4\u003c\/strong\u003e — dress panel; \u003cstrong\u003eTR-1-R\u003c\/strong\u003e optional trim ring for semi-flush mounting the cabinet; \u003cstrong\u003eBB-17F\u003c\/strong\u003e battery box for batteries above 7 Amp Hour.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the Fire•Lite Alarms manual \"Fire Alarm Control Panels MS-2 \u0026amp; MS-4, MS-2E \u0026amp; MS-4E Instruction Manual,\" document 51512 Rev. G3 (8\/6\/2014). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":43132870066400,"sku":"MS-4","price":916.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/fire-lite-control-panels-default-title-fire-lite-ms-4-fire-alarm-control-panel-4-zone-33036074909920.jpg?v=1763277694"},{"product_id":"fire-lite-es-50x-addressable-fire-alarm-control-panel-50-point","title":"Fire-Lite ES-50X 50-Point Addressable Fire Alarm Control Panel","description":"\u003cp\u003e\u003cstrong\u003eES-50X\u003c\/strong\u003e — intelligent addressable fire alarm control panel with one signaling line circuit, 50-point device capacity and a pre-installed IPOTS-COM dual-technology (IP and POTS) central station communicator.\u003c\/p\u003e\n\u003cp\u003eThe ES-50X is a direct replacement for the MS-9050UD and programs just like Fire•Lite’s other addressable panels, yet fits into applications previously served only by conventional panels. Its single SLC (DCL) loop supports any combination of addressable detectors and modules up to 50 devices, meets NFPA Class A or Class B requirements, and runs up to 10,000 ft. (3,000 m) in LiteSpeed mode over twisted, unshielded wire. Two independently programmable notification appliance circuits may each be configured Class A or Class B, with selectable strobe synchronization per NAC for System Sensor, Wheelock and Gentex appliances. The pre-installed IPOTS-COM communicator reports to a central station over the public switched telephone network and over the Internet, saving the monthly cost of two dedicated business telephone lines; optional cellular reporting is available using HW-TG7F Series communicators or the CLSS Pathway. The ES-50X ships as the main circuit board with display, pre-installed IPOTS-COM communicator, chassis with transformer, backbox with door, and a plastic bag containing screws, cables and key.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling line circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne intelligent SLC (DCL); meets NFPA Class B and Class A requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable device capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 (any combination of addressable detectors and modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnnunciators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (up to 8 per ANN-BUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiteSpeed and CLIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC wire run\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 ft. (3,000 m) in LiteSpeed mode, twisted unshielded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification appliance circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block provides connections for two NACs, Class B or Class A; special application power; power-limited, supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum signaling current per NAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A special application; 250 mA regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal 24 VDC system power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 A maximum, shared between all NAC circuits and the ANN-BUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC end-of-line resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7k ohm, ½ watt (P\/N 71252 UL listed) for Class B NAC; system capable of 1.9k–22k ohm ELR range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo programmable Form-C relays and one fixed trouble relay; 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive); non-power-limited, non-supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 or 240 VAC, 50\/60 Hz, 3.25 A, auto-sensing (no switch required); minimum 14 AWG (2.00 mm²) with 600 V insulation; non-power-limited, supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 12 V 18 AH lead-acid; charger capacity 7–18 AH; cabinet holds a maximum of two 18 AH batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral 80-character LCD with backlighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackbox\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.00\" (48.26 cm) H × 16.65\" (42.29 cm) W × 5.25\" (13.34 cm) D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.26\" (48.92 cm) H × 16.82\" (42.73 cm) W × 0.72\" (1.82 cm) D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.9 lbs. (12.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–49°C \/ 32–120°F, relative humidity 93% ± 2% RH noncondensing at 32°C ± 2°C (90°F ± 3°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eListed to UL Standard 864, 10th edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency listings (ES-50X)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL: S624; FM approved; CSFM 7165-0075:0500, 7165-0075:0511; FDNY COA #2021-TMCOAP-009618-AMD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower budget:\u003c\/strong\u003e the 2.5 A figure is per NAC. Maximum or total 24 VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A — size annunciators and notification load against that total, not against a single circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNAC count:\u003c\/strong\u003e the terminal block provides connections for two NACs. Each may be wired Class A or Class B; Class A does not add circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDress panel:\u003c\/strong\u003e the ES-50X carton does not include a dress panel (the ES-50XC, ES-50XI and ES-50XP do). Order DP-ES-R separately; TR-CE is the trim ring for semi-flush mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e the cabinet holds a maximum of two 18 AH batteries and the onboard charger covers 7–18 AH. Anything larger than 18 AH requires a CHG-75 or CHG-120F charger and an external enclosure such as BB-26 or BB-55F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy devices:\u003c\/strong\u003e 300 Series devices such as CP300\/CP350, SD300(T)\/SD350(T), M300, M301, M302, C304 and BG-10LX are not compatible with LiteSpeed polling. If any are on the SLC, polling must be set to standard CLIP protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e databases upload and download through the panel USB port, or over ethernet using the IPOTS-COM. Offline programming with FS-Tools requires an ethernet connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-50XC\u003c\/strong\u003e — same panel and pre-installed IPOTS-COM communicator, but the carton includes a dress panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-50XI\u003c\/strong\u003e — no communicator fitted; includes dress panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-50XP\u003c\/strong\u003e — integrated CLSS Pathway Pro dual-SIM (AT\u0026amp;T\/Verizon) 5G LTE-M communicator in place of the IPOTS-COM; listed under ETL 5017286 and CSFM 7165-0075:0511.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMS-9050UD\u003c\/strong\u003e — the legacy panel the ES-50X Series directly replaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the Fire•Lite Alarms data sheet \"ES-50X Series Intelligent Addressable Fire Alarm Control Panels,\" document DF-60953:D (3\/27\/2023). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":43132870099168,"sku":"ES-50X","price":946.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/fire-lite-control-panels-default-title-fire-lite-es-50x-addressable-fire-alarm-control-panel-50-point-34899778830560.jpg?v=1763277708"},{"product_id":"fire-lite-mrp-2002","title":"Fire-Lite MRP-2002 Agent Release Control Panel 120 VAC","description":"\u003ch2\u003eFire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe MRP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The MRP-2002 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing.\u003c\/p\u003e\n\u003cp\u003eThe MRP-2002 is compatible with System Sensor's i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory 'freeze' signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C).\u003c\/p\u003e\n\u003cp\u003eIn addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the FireLite Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits.\u003c\/p\u003e\n\u003cp\u003eThree programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MRP-2002 supervises all wiring, AC voltage, battery charger and battery level.\u003c\/p\u003e\n\u003cp\u003eActivation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel's LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.\u003c\/p\u003e\n\u003cp\u003eThe MRP-2002E offers the same features as the MRP-2002 but allows connection to 220\/240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 110\/ 120 VAC and 220\/240 VAC versions of the panels.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat’s Included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMRP-2002 Fire Alarm Control Panel\u003cbr\u003eBackbox\u003cbr\u003ePower Supply\u003cbr\u003eTechnical Manual\u003cbr\u003eInstruction Sheet\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeets International Building Code IBC seismic requirements\u003c\/li\u003e\n\u003cli\u003eAdjustable pre-discharge, discharge and waterflow delay timers.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDual hazard operation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeets International Building Code (IBC) seismic requirements.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDisable\/Enable control per input zone and output zone.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExtensive transient protection.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDual hazard operation.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCross-zone (double-interlock) capability.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSix programmable Style B (Class B) IDCs (Initiating Device Circuit).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":43132870721760,"sku":"MRP-2002","price":1403.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/FL-MRP2002_lg.jpg?v=1769120513"},{"product_id":"fire-lite-ms-10ud-7-10-zone-conventional-fire-control-panel","title":"Fire-Lite MS-10UD-7 10 Zone Conventional Fire Control Panel","description":"\u003cp\u003e\u003cstrong\u003eMS-10UD-7\u003c\/strong\u003e — ten-zone conventional fire alarm control panel with a built-in digital alarm communicator\/transmitter, supplied with the FLPS-7 power supply providing 7.0 amps total 24 VDC output current.\u003c\/p\u003e\n\u003cp\u003eThe MS-10UD combination control and digital communicator panel provides fire signaling protection for small to medium sized commercial, industrial and institutional buildings. It is compatible with System Sensor i3 conventional smoke detectors, which transmit a maintenance trouble signal indicating the need for cleaning and a supervisory freeze signal when ambient temperature falls below approximately 45°F, and with conventional input devices such as two-wire and four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Outputs include four NACs, three programmable Form-C relays factory programmed for alarm, trouble and supervisory, and 24 VDC special application resettable and nonresettable power. The panel supervises all wiring, AC voltage, battery level and telephone line integrity. The integral DACT reports system status to a central station over the public switched telephone network and supports remote programming or interrogation with the PS-Tools upload\/download utility; local programming is possible through the panel USB port.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitiating device circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTen programmable IDCs, all Style B (Class B); zones 1–5 on TB4 and zones 6–10 on TB6; supervised and power-limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDC normal operating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 20 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDC alarm current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDC short circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDC maximum loop resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ohms (700 ohms per zone for linear heat detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDC standby current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification appliance circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour NACs, Style Y (Class B), special application power, supervised and power-limited; nominal 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum signaling current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 amps for MS-10UD-7(E): 3.0 amps special application, 300 mA regulated maximum per NAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel current budget (FLPS-7)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm 7.0 amps max per panel; standby 1.0 amp max per panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnd-of-line resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7k ohm, 1\/2 watt (Part #71252) for both IDCs and NACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz, 3.90 amps (FLPS-7); minimum #14 AWG (2.0 mm²) with 600 V insulation; supervised, nonpower-limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSealed lead acid only; maximum charging circuit normal flat charge 27.6 VDC @ 1.4 amp; supervised, nonpower-limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum charger capacity 26 Amp Hour; minimum battery size 7 Amp Hour; cabinet houses two 18 Amp Hour batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm-C relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree programmable (TB8): Relay 1 alarm, Relay 2 fail-safe trouble, Relay 3 supervisory; contacts 2 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecial application resettable power (TB9)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC, 500 mA maximum, power-limited — appropriate for powering 4-wire smoke detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResettable \/ nonresettable power (TB9)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC, 500 mA maximum, power-limited; jumper selectable by JP31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary ANN-BUS power (TB3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC, 500 mA maximum, power-limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in DACT; two modular phone jacks (PH1 primary, PH2 secondary); Touch-Tone default, programmable to rotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80-character (4 lines × 20 characters) backlit LCD; 25-key panel including a 16-key alpha-numeric pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory log\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrobe synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Sensor, Wheelock, Gentex, Faraday, Amseco\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCertified to comply with the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864, 9th Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass A is not standard:\u003c\/strong\u003e the IDCs are Style B (Class B) and the NACs are Style Y (Class B). Class A operation requires the optional CAC-5X Class A Converter Module for NACs and IDCs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-circuit vs panel budget:\u003c\/strong\u003e each NAC is rated 3.0 amps special application, but the FLPS-7 supplies 7.0 amps total alarm current per panel. Four circuits at 3.0 A each cannot be loaded simultaneously — size the whole panel, not one circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery sizing:\u003c\/strong\u003e the onboard charger handles up to 26 AH on the -7, but the cabinet itself only houses two 18 Amp Hour batteries. Anything larger requires a separate battery box such as the BB-26 or BB-55F together with a CHG-75 or CHG-120F charger. Minimum battery size is 7 Amp Hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote sync output:\u003c\/strong\u003e the TB2 remote power supply synchronization output is only required for the MS-5UD-3(E) and MS-10UD-3(E). It is not part of the FLPS-7 current distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemi-flush mounting:\u003c\/strong\u003e do not recess the box more than 3.875\" into the wall, to avoid covering the venting holes on top of the box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnnunciation:\u003c\/strong\u003e the ANN-BUS connects the ANN-80 remote LCD annunciator, ANN-I\/O LED driver, ANN-S\/PG printer module, ANN-RLY relay module and ANN-LED annunciator module. A secondary ANN-BUS requires the optional ANN-SEC card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDress panel:\u003c\/strong\u003e DP-51050 is optional on this model. Canadian models supply a modified dress panel including an ANN-LED annunciator module as standard. TR-CE (red) is the optional trim ring for semi-flush mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMS-10UD-3\u003c\/strong\u003e — ten-zone, 120 VAC with FLPS-3 power supply providing 3.0 amps total 24 VDC output (2.5 amps special application, 250 mA regulated maximum per NAC); draws 120 VAC, 60 Hz, 1.00 amp.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMS-10UD-7E\u003c\/strong\u003e — same as MS-10UD-7 but 240 VAC, 50 Hz, 2.20 amps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMS-10UD-7C\u003c\/strong\u003e — includes a built-in ANN-LED annunciator and is approved for Canadian applications; minimum battery size is 12 Amp Hour and maximum charger capacity is 18 Amp Hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMS-5UD-7\u003c\/strong\u003e — five-zone version of the same platform with the FLPS-7 power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the Fire•Lite Alarms manual \"Fire Alarm Control Panels MS-5UD \u0026amp; MS-10UD Series Manual,\" document 52626 Rev. C7 (6\/12\/2018). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":43132870852832,"sku":"MS-10UD-7","price":1320.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/fire-lite-control-panels-default-title-fire-lite-ms-10ud-7-10-zone-conventional-fire-control-panel-34052884988128.jpg?v=1763277728"},{"product_id":"fire-lite-ecc-50-100-emergency-command-center","title":"Fire-Lite ECC-50\/100 Emergency Command Center","description":"\u003cp\u003e\u003cstrong\u003eECC-50\/100\u003c\/strong\u003e — multipurpose emergency voice evacuation panel (Primary Operating Console) for fire applications, mass notification applications, or both, with a built-in 25 Vrms 50 watt amplifier and a single speaker circuit as standard.\u003c\/p\u003e\n\u003cp\u003eThe ECC-50\/100 comes with fourteen field programmable messages of up to 60 seconds each, built-in field configurable pre- and post-announce tone generators, an integral supervised microphone, and a fully supervised notification appliance circuit with 2.0 amps of synchronized NAC power. A secondary 50 watt amplifier (ECC-50W-25V or ECC-50W-70V) can be added for single-circuit backup or to raise the system to two speaker circuits and 100 watts; an optional ECC-CE6 module expands the panel to a maximum of eight speaker circuit outputs. All speaker output circuits can be wired Style Y (Class B) or Style Z (Class A). For fire protection applications the ECC-50\/100 is an adjunct (slave) to any UL listed FACP via reverse polarity or contact closure, and can be used as a stand-alone unit for non-fire applications. Seamless integration is available by direct serial activation from an ES-200X, MS-9600(UD)LS or MS-9200UDLS over the ANN\/ACS (EIA-485) link; other panels drive the eight onboard command input circuits. The system expands with up to eight external remote consoles and up to eight distributed audio amplifiers on the external data and audio riser buses. All programming is done through a built-in programming utility accessed from a laptop.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in audio power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 watts, 25 Vrms; expandable to 100 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeaker circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 built in (second requires the optional amplifier); expandable to 8 with ECC-CE6; each Style Y (Class B) or Style Z (Class A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeaker circuit rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 Vrms @ 2 amps max, maximum load impedance 12.5 ohms; 70.7 Vrms @ 700 mA max with maximum load impedance 100 ohms using the ECC-XRM-70V conversion transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeaker output power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 watts (10 watts when background music is employed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 Hz – 4,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeaker circuit capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum total 250 µF per speaker circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeaker circuit EOL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15k ohm, 1 watt (P\/N ELR-15K) required for Style Y (Class B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMessages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 recorded, field selectable, up to 60 seconds each; custom recording via local microphone, USB port or external audio input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification appliance circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne Style Y (Class B) or Style Z (Class A); nominal 24 VDC; 2.0 A special application, 200 mA regulated; maximum wiring impedance 1 ohm; power-limited (Class 2), supervised; EOL 4.7k ohm ½ watt (P\/N 71252) for Style Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommand input circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEight; CMD1 and CMD2 field selectable for 12 or 24 VDC NAC reverse polarity or contact closure, CMD3–CMD8 contact closure only; operating range 10.5–29 VDC; reverse polarity current 1.6 mA max; contact closure current 6.6 mA max (requires 4.7k ohm ½ watt EOL, P\/N 27072); maximum wiring impedance 200 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm-C relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree — AC power loss, system trouble, and MNS active; each rated 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecial application (auxiliary) power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA @ 24 VDC, power-limited; for addressable modules and end-of-line power supervision relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal operator interface power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC, 0.80 amps maximum; non-resettable, power-limited, non-supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeaker volume control override\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStyle Y or Style Z; nominal 24 VDC; 0.25 amps maximum; EOL 4.7k ohm ½ watt (P\/N 71252)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC follower \/ remote sync\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrigger input 9 to 32 VDC, 24 VDC rated; 10 mA input draw in alarm at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNight ring input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact closure, isolated and non-supervised; 3.8 mA maximum; maximum wiring impedance 30k ohms; minimum isolation withstand 1500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal audio input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput impedance 8.5k ohms nominal @ 1 kHz; 700 mV rms maximum; 0.1 mA maximum @ 700 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz, 3.5 amps; minimum #14 AWG (2.00 mm²) with 600 V insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLead-acid only; float charge voltage 27.3 V; maximum charge current 1.0 amp; maximum battery charge capability 26 AH; minimum battery size 12 Amp Hour; ECC cabinet holds a maximum 18 AH battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory log\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFully loaded system capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 watts total distributed audio power; 24 speaker circuits; 8 remote consoles; 8 distributed audio amplifiers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackbox\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.0\" (48.26 cm) high × 16.65\" (42.29 cm) wide × 5.20\" (13.23 cm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.26\" (48.92 cm) high × 16.82\" (42.73 cm) wide × 0.12\" (0.30 cm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase unit 27.85 lbs. (12.63 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–49°C \/ 32–120°F, relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 864; UL 2572; UFC 4-021-01; IBC 2012, 2009, 2006, 2003, 2000 (seismic); CBC 2007 (seismic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL\/ULC Listed S2424; CSFM 6911-0075:0226; NYC Fire Dept. Certificate of Approval #6152; FM Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackground music costs output:\u003c\/strong\u003e speaker circuit output power is 50 watts, but drops to 10 watts when background music is employed. Design the speaker load against 10 watts if music is part of the application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery minimum is 12 AH, not 7:\u003c\/strong\u003e the charger supports up to 26 AH, but the ECC cabinet holds a maximum 18 AH battery, and the minimum battery size is 12 Amp Hour. Larger batteries need an external CHG-75 or CHG-120F charger.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo different EOL resistors:\u003c\/strong\u003e speaker circuits use a 15k ohm 1 watt ELR-15K, while the NAC and speaker volume control override use 4.7k ohm ½ watt (P\/N 71252). Command input contact-closure circuits call for a 4.7k ohm ½ watt resistor under a different part number, P\/N 27072. Do not standardize on one resistor across the panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot a fire alarm control panel:\u003c\/strong\u003e for fire protection applications the ECC-50\/100 is an adjunct (slave) to a UL listed FACP. Stand-alone operation is for non-fire applications only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMass notification changes the inputs:\u003c\/strong\u003e when the system is programmed for Mass Notification, CMD1 and CMD2 are programmed for reverse polarity only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e70 volt operation:\u003c\/strong\u003e the primary amplifier reaches 70.7 Vrms only with the ECC-XRM-70V transformer plugged into J12 of the main control board, or by choosing the ECC-50W-70V for the secondary amplifier. Speaker wiring remains supervised in standby, alarm and during background music with the optional transformer installed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeismic:\u003c\/strong\u003e certified for seismic applications with the appropriate mounting kit — SEISKIT-COMMENC, which includes a battery bracket for two 12 AH or 18 AH batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eECC-50\/100E\u003c\/strong\u003e — export version, 240 VAC, 50 Hz, 2.0 amps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECC-CE6\u003c\/strong\u003e — speaker circuit\/zone expander module providing up to six additional Style Y or Style Z speaker circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECC-50W-25V \/ ECC-50W-70V\u003c\/strong\u003e — 50 watt secondary amplifier modules at 25 V or 70 V; add a second speaker circuit or serve as a backup amplifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECC-XRM-70V\u003c\/strong\u003e — 70 V transformer conversion module for the primary amplifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECC-LOC \/ ECC-RPU \/ ECC-RM\u003c\/strong\u003e — local operator console, remote page unit and remote microphone; up to eight remote consoles in any combination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECC-50DA \/ ECC-125DA \/ ECC-50BDA\u003c\/strong\u003e — distributed audio amplifiers of 50, 125 and 100 watts; up to eight in any combination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECC-FFT\u003c\/strong\u003e — firefighter telephone system option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the Fire•Lite Alarms data sheet \"ECC-50\/100(E) Emergency Command Center,\" document DF-60734:B1 (8\/15\/2018). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":43132871049440,"sku":"ECC-50\/100","price":2843.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/fire-lite-control-panels-default-title-fire-lite-ecc-50-100-emergency-command-center-31896796791008.jpg?v=1763277743"},{"product_id":"fire-lite-mrp-2001-pre-action-deluge-control-panel","title":"Fire-Lite MRP-2001 Deluge Preaction Releasing Control Panel, Six Zone, 24V, 120 VAC","description":"\u003cp\u003e\u003cstrong\u003eFire-Lite MRP-2001\u003c\/strong\u003e — six zone deluge and preaction releasing control panel for single and dual hazard water based systems.\u003c\/p\u003e\u003cp\u003eIt detects, signals and releases in one enclosure: conventional initiating devices report to six zones, and four programmable outputs drive either releasing solenoids or notification appliances.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSix programmable Style B (Class B) initiating device circuits; 4.7 kΩ half watt end-of-line resistor, maximum loop resistance 100 Ω\u003c\/li\u003e\n\u003cli\u003eFour programmable Style Y (Class B) outputs, each assignable as a releasing or notification appliance circuit\u003c\/li\u003e\n\u003cli\u003e7.0 A total 24 VDC output current, of which 3.0 A is special application power\u003c\/li\u003e\n\u003cli\u003eAdjustable waterflow discharge timer, two soak timers, cross zone double interlock\u003c\/li\u003e\n\u003cli\u003eThree programmable Form C relays rated 2 A at 30 VDC resistive\u003c\/li\u003e\n\u003cli\u003e120 VAC 60 Hz at 3.66 A; UL 864 9th edition listed and FM approved for NFPA 13, 15 and 16 systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eMRP-2001E is the same panel wired for 240 VAC and MRP-2001C the ULC listed Canadian model. MRP-2002 is the agent release panel for clean agent rather than water. Class A wiring needs the CAC-5X module.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":43132872163552,"sku":"MRP-2001","price":1210.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/fire-lite-control-panels-default-title-fire-lite-mrp-2001-pre-action-deluge-control-panel-35022886502624.jpg?v=1763277781"},{"product_id":"simplex-4010-9912-serial-dact","title":"Simplex 4010-9912 Serial DACT","description":"\u003ch2\u003eSimplex 4010-9912 Serial DACT\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003eSimplex serial digital alarm communicating transmitter (SDACT) modules monitor the status of the host fire alarm control panel and its connections to the Central Station monitoring location\u003cbr\u003e\u003cbr\u003eWhen status changes require information to be reported, the SDACT provides detailed messages that can assist the Central Station in accurately implementing the required response. Typical information reports include alarms, troubles, and supervisory conditions. Model series 4007ES, 4010, 4010ES, 4100ES, and 4100U provide specific point information.\u003cbr\u003e\u003cbr\u003eSDACT modules directly communicates with the fire alarm control panel CPU and are custom programmed for the specific requirements of the Central Station and the connected fire alarm control panel.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":43132905226464,"sku":"4010-9912","price":354.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/simplex-fire-alarms-default-title-simplex-4010-9912-serial-dact-31897041436896.jpg?v=1763278136"},{"product_id":"napco-fl-32facp-ltevs-integrated-fire-alarm-control","title":"Napco FL-32FACP-LTEVS Integrated Fire Alarm Control","description":"\u003ch2\u003eNapco FL-32FACP-LTEVS Integrated Fire Alarm Control Unit\u003c\/h2\u003e","brand":"Napco","offers":[{"title":"Default Title","offer_id":43133040132320,"sku":"FL-32FACP-LTEVS","price":601.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/napco-control-panels-default-title-napco-fl-32facp-ltevs-integrated-fire-alarm-control-31896899092704.jpg?v=1763280437"},{"product_id":"mircom-fr-320-r-dual-releasing-special-hazard-suppression-control-unit","title":"Mircom FR-320-R Dual Releasing Special Hazard Suppression Control Unit","description":"\u003cdiv class=\"elementor-element elementor-element-4dfb473 elementor-widget elementor-widget-woocommerce-product-short-description\" data-id=\"4dfb473\" data-element_type=\"widget\" data-widget_type=\"woocommerce-product-short-description.default\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cdiv class=\"woocommerce-product-details__short-description\"\u003e\n\u003ch2\u003eMircom FR-320-R Field configurable for use on deluge sprinkler systems, pre-action sprinkler systems and agent release systems\u003c\/h2\u003e\n\u003cp\u003eMircom’s FR-320 is a dual releasing special hazard suppression control unit that is field configurable for use on Deluge Sprinkler Systems, Pre-Action Sprinkler Systems and Agent Release Systems.\u003c\/p\u003e\n\u003cp\u003eThe mode of operation is easily configured by selecting one of 14 pre-configured modes of operation. The simple configuration process is done via the front panel and requires no laptop or complicated programming.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mircom","offers":[{"title":"Default Title","offer_id":43133041475808,"sku":"FR-320-R","price":1404.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/mircom-control-panels-default-title-mircom-fr-320-r-dual-releasing-special-hazard-suppression-control-unit-38307127656672.jpg?v=1763280456"},{"product_id":"silent-knight-6700-addressable-fire-alarm-control-panel","title":"Silent Knight 6700 Addressable Fire Alarm Control Panel","description":"\u003cp\u003e\u003cstrong\u003e6700\u003c\/strong\u003e — compact intelligent addressable fire alarm control panel with a built-in dual-technology (IP and POTS) communicator, rated for 100 SK points or 50 SD points.\u003c\/p\u003e\u003cp\u003eThe 6700 is the latest intelligent addressable FACP from Silent Knight and is a direct replacement for the 5700. It has one SLC loop for connecting addressable detectors, supporting 50 System Sensor SK sensors and 50 SK modules, or 50 Hochiki SD devices per loop; total point capacity is a maximum of 100 points per panel with IDP and SK devices, or 50 points per panel using SD devices. Two onboard Flexput circuits can be configured as notification outputs or auxiliary power, with four types of auxiliary power available — door holder, constant power, resettable power and sounder sync power. The panel also provides a form-C trouble relay and two programmable form-C relays, plus drift compensation, pre-trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and a calibration trouble alert. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable, with one designated panel acting as communicator for the whole link.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent signaling line circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable device capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 (SK) or 50 (SD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevices per SLC loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 SK sensors and 50 SK modules, or 50 SD devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (expandable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSBUS devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (8 annunciators, 8 LED modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour-line LCD, 20 characters per line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz, 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e165 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlexput circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block provides connections for two Class B or one Class A NACs or auxiliary power; power-limited, supervised circuitry. Maximum current per circuit 1 A @ 27.4 VDC. End-of-line resistor 4.7k ohm, ½ watt for Class B NAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal power output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A max @ 27.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupervised and power-limited, Class A or Class B, 32 VDC, 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay contact rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A @ 27.4 VDC (resistive), Form C — two programmable relays and one fixed trouble relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCabinet holds a maximum of two 7 AH batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery charger capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 to 35 AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.71\" W x 15.12\" H x 3.33\" D (32.28 cm x 38.41 cm x 8.46 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 lbs. (6.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification cadence patterns\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 preset patterns, including ANSI 3.41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets NFPA requirements for operation at 0 to 49°C (32 to 120°F) and 93% ± 2% RH non-condensing at 32°C ± 2°C (90°F ± 3°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 864 10th Edition; complies with NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed S2766; CSFM 7165-0559:0501; FDNY COA# 6298A; Seismic (CA) VMA-45894-05C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-circuit and total Flexput ratings are different numbers:\u003c\/strong\u003e each Flexput circuit is limited to 1 A @ 27.4 VDC, while the panel's total power output is 2.5 A max @ 27.4 VDC. The headline \"two Flexput circuits, 2.5 amps max\" describes the combined panel output, not 2.5 A on each circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass A halves the circuit count:\u003c\/strong\u003e the terminal block yields either two Class B NACs or one Class A NAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSK and SD devices cannot be mixed\u003c\/strong\u003e in the same system, and the choice sets the ceiling: 100 points with SK, only 50 with SD. Refer to the Device Compatibility Document and SLC Wiring Manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery headroom is in the cabinet, not the charger:\u003c\/strong\u003e the charger is rated 7 to 35 AH but the cabinet only holds up to two 7 AH batteries, so larger standby calculations require an external battery enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd-of-line resistor:\u003c\/strong\u003e 4.7k ohm, ½ watt on Class B NAC circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless expansion:\u003c\/strong\u003e the panel supports up to four SWIFT wireless gateways, each of which can foster up to 49 wireless devices. SWIFT is compatible with System Sensor (SK) devices only, not Hochiki (SD).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended ambient is narrower than the listed range:\u003c\/strong\u003e although the system meets NFPA requirements to 120°F, Honeywell recommends a normal room temperature of 15 to 27°C (60 to 80°F) to avoid shortening battery and component life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e the cabinet can be surface or flush mounted.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRelated models\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5700\u003c\/strong\u003e — the previous-generation panel the 6700 directly replaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6820\u003c\/strong\u003e — the larger platform in the same family, expandable to 1,110 SK points with six Flexput circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5895XL\u003c\/strong\u003e — 6 A power supply module with six Flexput circuits and two Form C relays, for adding notification power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6860 \/ 6855 \/ 5860 \/ 5860R\u003c\/strong\u003e — LCD remote fire annunciators; \u003cstrong\u003e5865-3\u003c\/strong\u003e and \u003cstrong\u003e5865-4\u003c\/strong\u003e LED annunciators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5880\u003c\/strong\u003e — LED I\/O module with 40 programmable LED outputs and eight supervised dry contact inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5883\u003c\/strong\u003e — relay interface providing 10 Form C relays\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5824\u003c\/strong\u003e — serial\/parallel printer interface module for printing system reports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWSK-WGI\u003c\/strong\u003e — SWIFT wireless gateway, up to four supported per panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eSpecifications taken from the Honeywell Silent Knight data sheet \"6700 Intelligent Fire Alarm Control Panel with Communicator,\" document 351607:C (3\/8\/2022). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Silent Knight","offers":[{"title":"Default Title","offer_id":43133102784736,"sku":"6700","price":930.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/silent-knight-control-panels-default-title-silent-knight-6700-addressable-fire-alarm-control-panel-31896992547040.jpg?v=1763280677"},{"product_id":"silent-knight-6808-fire-alarm-control-panel-198-point","title":"Silent Knight 6808 Fire Alarm Control Panel 198-Point","description":"\u003cp\u003e\u003cstrong\u003e6808\u003c\/strong\u003e — Silent Knight intelligent addressable fire alarm control panel with built-in dual-path communicator, in a red surface- or flush-mountable enclosure. It is the latest intelligent addressable FACP from Silent Knight and a direct replacement for the 5808 FACP.\u003c\/p\u003e\n\u003cp\u003eThe 6808 has one SLC (signaling line circuit) loop for connecting addressable detectors, supporting 99 System Sensor SK sensors and 99 SK modules — 198 addresses — or 127 Hochiki SD devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable, with a designated panel configured as the communicator for all panels in the link for single-point communications. The built-in digital alarm communicator\/transmitter is dual technology, IP and POTS: the POTS path transmits system status to a central station over the public switched telephone network, while the IP communicator sends alarm signals over the internet, saving the monthly cost of two dedicated business telephone lines. Optional cellular reporting is available.\u003c\/p\u003e\n\u003cp\u003eFour onboard output circuits can be configured as notification outputs or as auxiliary power in four types — door holder, constant, resettable and sounder sync power. The panel also provides a form-C trouble relay and two programmable form-C relays, plus drift compensation, pre-trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and a calibration trouble alert. JumpStart auto programming, a built-in USB interface and the Windows-based Honeywell Fire Software Suite (HFSS) simplify commissioning, and firmware is field-upgradeable. SWIFT wireless support allows up to four wireless gateways, each fostering up to 49 wireless devices.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent signaling line circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable device capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e198 (SK) or 127 (SD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 (plus 250 output groups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (expandable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSBUS devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 (12 annunciators, 8 LED modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz, 3.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput circuits detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour Class B or two Class A NACs or auxiliary power; power-limited, supervised. Max. 3 A per circuit, not to exceed 6 A total for all circuits. EOL resistor 4.7k ohm, ½ watt for Class B NACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupervised and power-limited, Class A or Class B, 32 VDC, 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo programmable and one fixed trouble relay; 2.5 A @ 27.4 VDC (resistive), Form C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCabinet holds maximum of two 18 AH batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery charger capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17–55 AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.4″ W × 26.4″ H × 4.1″ D (41.66 × 67.06 × 10.41 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 lbs. (20.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour line LCD, 20 characters per line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 event capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature \/ humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets NFPA requirements for 32–120°F (0–49°C) and 93% ±2% RH non-condensing at 90°F ±3°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with UL 864 10th Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2766\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCSFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7165-0559:0502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFDNY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOA# 2023-TMCOAP-001168-RENL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeismic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(CA) VMA-45894-05C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSK and SD devices cannot be mixed\u003c\/strong\u003e in the same system. Choose one protocol family and refer to the Device Compatibility Document and SLC Wiring Manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput circuit budget:\u003c\/strong\u003e each of the four circuits is rated 3 A maximum, but the total across all circuits cannot exceed 6 A — size notification loads against the 6 A ceiling, not 4 × 3 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNAC end-of-line:\u003c\/strong\u003e Class B NACs require a 4.7k ohm, ½ watt end-of-line resistor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrobe synchronization\u003c\/strong\u003e is selectable for Amseco, System Sensor, Wheelock and Gentex devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSWIFT wireless is only compatible with System Sensor (SK) devices\u003c\/strong\u003e — it is not compatible with Hochiki (SD) devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery sizing:\u003c\/strong\u003e the cabinet physically holds a maximum of two 18 AH batteries; larger capacities up to the 55 AH charger limit require the RBB remote battery box accessory cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e although rated to NFPA limits, installation in a normal room temperature of 60–80°F (15–27°C) is recommended, since extreme temperature and humidity shorten standby battery and component life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel linking:\u003c\/strong\u003e connectivity for up to 17 sites requires the SK-NIC network interface card; fiber runs use SK-FML (multi-mode) or SK-FSL (single-mode).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models and accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5808\u003c\/strong\u003e — the previous-generation FACP that the 6808 directly replaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6860 \/ 6855 \/ 5860 \/ 5860R\u003c\/strong\u003e — LCD remote fire annunciators (6860 is 4x40 with four programmable buttons, red).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5895XL\u003c\/strong\u003e — 6 A power supply with six Flexput circuits and two Form C relays; \u003cstrong\u003e5496\u003c\/strong\u003e — 6 A NAC power expander with four power-limited outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWSK-WGI\u003c\/strong\u003e — SWIFT wireless gateway; up to four supported, 49 wireless devices each.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHWF2A-COM \/ HWF2V-COM \/ IPGSM-4G\u003c\/strong\u003e — optional cellular and dual-path fire alarm communicators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSK-SCK\u003c\/strong\u003e — seismic compliance kit; \u003cstrong\u003eRBB\u003c\/strong\u003e — remote battery box accessory cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the Silent Knight (Honeywell) data sheet “6808 Intelligent Fire Alarm Control Panel with Communicator,” document 351608, Rev. D (5\/22\/2023). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Silent Knight","offers":[{"title":"Default Title","offer_id":43133102850272,"sku":"6808","price":1382.55,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/silent-knight-control-panels-default-title-silent-knight-6808-fire-alarm-control-panel-198-point-31896996053216.jpg?v=1763280658"},{"product_id":"napco-gem-p9600-powerful-multi-tasking-hybrid-control-panel","title":"Napco GEM-P9600 Gemini Burglary and Residential Fire Control Panel\/Communicator, 8 to 96 Zones","description":"\u003cp\u003e\u003cstrong\u003eNapco GEM-P9600\u003c\/strong\u003e — Gemini hardwire and wireless burglary and residential fire control panel with integral digital communicator.\u003c\/p\u003e\u003cp\u003eNapco lists UL 1023 household burglar and UL 985 household fire warning, plus UL 609, UL 1610 and UL 365 burglar listings. No UL 864 listing appears, so it is a household fire panel, not a commercial fire alarm control unit.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e8 on-board zones, expandable to 96 with expansion modules, wireless receivers and 4-zone keypads\u003c\/li\u003e\n\u003cli\u003e8 partitions, 96 user codes, 15 keypads, 800-event log\u003c\/li\u003e\n\u003cli\u003eFire zones accept 2-wire and 4-wire 12 VDC smoke detectors\u003c\/li\u003e\n\u003cli\u003ePowered from a 16.5 VAC Class 2 plug-in 40 VA or 50 VA transformer (TRF11 or TRF14)\u003c\/li\u003e\n\u003cli\u003eResidential fire or combination fire and burglary: 24 hours standby on an RBAT7 12 VDC 7 Ah battery, 150 mA standby, 650 mA alarm\u003c\/li\u003e\n\u003cli\u003eRelay outputs 12 VDC 1.2 A wet or 24 VDC 2 A dry; board 12 3\/8 × 13 7\/8 × 3 1\/2 in. without cover\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eKeypads, transformer and battery are separate catalogue numbers. CSFM describes a board in a Model H299 enclosure; GEM-P9600M is the mercantile version in the H217 enclosure via the H1217 kit, where Napco says not to use fire zones.\u003c\/p\u003e","brand":"Napco","offers":[{"title":"Default Title","offer_id":43133154558176,"sku":"GEM-P9600","price":383.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/napco-control-panels-default-title-napco-gem-p9600-powerful-multi-tasking-hybrid-control-panel-31896894734560.jpg?v=1763280776"},{"product_id":"potter-afc-100","title":"Potter AFC-100 Fire Alarm Control Panel","description":"\u003ch2\u003ePotter AFC-100  Addressable 100 Point Fire Alarm Control Panel\u003c\/h2\u003e\n\u003cp\u003eThe AFC-100 is an analog\/addressable fire alarm system with a total system capacity of 100 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC).\u003c\/p\u003e\n\u003cp\u003eThe AFC-100 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input\/Output (I\/O) circuits. The NACs are rated at 3 Amps each and the I\/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper\/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together.\u003c\/p\u003e\n\u003cp\u003eThe NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the AFC-100 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN-1000E has space to allow the installation of up to six loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":43488496681184,"sku":"AFC-100","price":938.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/potter-control-panels-default-title-potter-afc-100-fire-alarm-control-panel-36338453283040.png?v=1763281206"},{"product_id":"potter-pfc-6006-r-6-zone-sprinkler-monitoring-panel","title":"Potter PFC-6006-R 6 Zone Sprinkler Monitoring Panel","description":"\u003ch2\u003ePotter PFC-6006-R 6 Zone Sprinkler Monitoring Panel Red Cabinet (Conventional Fire Panel for Small or Fire Sprinkler Systems) \u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe PFC-6006 is a listed small conventional fire system ideally suited to monitor a small fire system such as a fire sprinkler system. The first input is selectable as a Class A or Class B water flow input and the other five zones are selectable from a menu of options including two-wire smoke detection. The panel has a 1.0 amp power supply that powers the panel, charges the batteries and supplies 0.5 amps to a notification appliance circuit and 0.5 amps of auxiliary power. The auxiliary power is programmable as constant or resettable.\u003c\/p\u003e\n\u003cp\u003eThe control panel is in a metal cabinet with a key lock and lexan window for viewing the system status. The printed circuit assembly is mounted for quick removal and installation to allow the cabinet to be installed with minimal effort. The cabinet houses up to two 12VDC, 18 AH batteries.\u003c\/p\u003e\n\u003cp\u003eThe display is a thirty-two (32) character LCD with system status LEDs. The system status is clearly displayed and the panel includes a history buffer for past events. The key pad allows navigation into the system menu, limited programming and system control. The condition and events on the panel are clearly displayed to allow the user and installer to determine the system status.\u003c\/p\u003e\n\u003cp\u003eThe panel has a dual telephone line digital alarm communicator transmitter (DACT) built on-board. One or both telephone lines may be enabled to allow communication to a remote monitoring station. In addition, an updated panel configuration may be sent to the panel through the telephone lines. The panel has line in and line out to allow the panel to be installed ahead of other telephone equipment on the premises.\u003c\/p\u003e\n\u003cp\u003eThe panel will support up to four (4) of the RA-6075 remote annunciators on the P-Link bus. These annunciators include a metal enclosure with a key lock and provide full functionality of the system.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":43701212971232,"sku":"PFC-6006-R","price":600.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/potter-control-panels-default-title-potter-pfc-6006-r-6-zone-sprinkler-monitoring-panel-38200235983072.png?v=1763281341"},{"product_id":"potter-pfc-4064-conventional-fire-alarm-control-panel-replaces-fpd-7024","title":"Potter PFC-4064 Conventional Fire Alarm Control Panel","description":"\u003ch2\u003eThe PFC-4064 Conventional Fire Panel is a compact, expandable panel designed to monitor all facets of a fire alarm system and communicate the status to a monitoring station (Replaces FPD-7024)\u003c\/h2\u003e\n\u003cp\u003eThe PFC-4064 panel is a listed and approved microprocessor-based conventional fire panel and complies with UL-864, NFPA-70, and NFPA-72. The panel is provided with six (6) inputs and four (4) 24VDC, 3.0 Amp Notification Appliance Circuits (NAC) with strobe synchronization.\u003c\/p\u003e\n\u003cp\u003eThe 5.0 Amp power supply provides ample power to meet any jurisdictions requirements and will charge up to 55 amp hours and house up to 12 amp hours. In addition, the panel has the Potter P-Link for connection to system accessories. The panel also has a 1.0 Amp auxiliary power output for controlling ancillary fire alarm functions.\u003cbr\u003e\u003cbr\u003eThe control panel is in a metal cabinet with a key lock and lexan window for viewing the system status. The printed circuit assembly is mounted for quick removal and installation to allow the cabinet to be installed with minimal effort. The cabinet houses up to two 12VDC, 18 AH batteries.\u003cbr\u003e\u003cbr\u003eThe display is an eighty (80) character LCD with system status LEDs. The system status is clearly displayed and the panel includes a history buffer for past events.\u003c\/p\u003e\n\u003cp\u003eThe key pad allows navigation into the system menu, limited programming and system control. The condition and events on the panel are clearly displayed to allow the user and installer to determine the system status.\u003cbr\u003e\u003cbr\u003eThe panel will support up to thirty-one (31) system accessories.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":43702306242784,"sku":"PFC-4064","price":1058.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/potter-control-panels-default-title-potter-pfc-4064-conventional-fire-alarm-control-panel-replaces-fpd-7024-32223434408160.jpg?v=1763281379"},{"product_id":"potter-afc-1000-fire-alarm-control-panel","title":"Potter AFC-1000 Fire Alarm Control Panel","description":"\u003ch2\u003ePotter AFC-1000 Fire Alarm Control Panel 1270 Point Addressable\u003c\/h2\u003e\n\u003cp\u003eThe AFC-1000 is an expandable analog\/addressable releasing fire alarm system with a total system capacity of 1270 addresses. Additional capacity on the system is achieved using multi-point SLC modules The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. The system is expandable with a total of nine additional addressable Signaling Line Circuits (SLC) each with a maximum of 127 devices. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC).\u003c\/p\u003e\n\u003cp\u003eThe AFC-1000 has a 10 Amp power supply with six Notification Appliance Circuits (NACs) and four Input\/Output (I\/O) circuits. The NACs are rated at 3 Amps each and the I\/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper\/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The I\/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously.\u003c\/p\u003e\n\u003cp\u003eThe NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the AFC-1000 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN-1000E has space to allow the installation of up to six PAD100-SLCE SLC loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":43702824894688,"sku":"AFC-1000","price":1402.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/potter-control-panels-default-title-potter-afc-1000-fire-alarm-control-panel-31896900305120.jpg?v=1763281516"},{"product_id":"silent-knight-6820evs-1110-point-addressable-fire-alarm-control-panel","title":"Silent Knight 6820EVS 1110-Point Addressable Fire Alarm Control Panel","description":"\u003cp\u003e\u003cstrong\u003e6820EVS\u003c\/strong\u003e — intelligent addressable fire alarm control panel with an integrated Emergency Voice System in a single enclosure, expandable to 1,110 SK points.\u003c\/p\u003e\u003cp\u003eThe 6820EVS combines an intelligent addressable FACP with an Emergency Voice System and is a direct replacement for the 5820XL-EVS. When the EVS features are enabled they are integrated with the fire alarm and voice evacuation functions of the control panel. Emergency voice operation includes an onboard supervised microphone, and all-call and non-active call buttons quickly select all active or all non-active output groups. The system allows emergency messages to be given priority over fire, holds 15 recordable one-minute messages that can be mapped to eight EVS buttons, and is capable of producing 520 Hz tones to meet NFPA 72 requirements. Up to four LOC consoles and eight addressable amplifiers are supported.\u003c\/p\u003e\u003cp\u003eOn the fire side the panel has one built-in signaling line circuit supporting 159 SK detectors and 159 SK modules, or 127 SD protocol devices, with additional SLC loops added for a maximum of 1,110 (SK) or 635 (SD) points. Six onboard Flexput circuits serve as notification outputs or auxiliary power, alongside a form-C trouble relay and two programmable form-C relays. The built-in DACT is dual technology, IP and POTS, with optional cellular reporting. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. The 6820EVS panels and accessories provide features to meet the requirements for Mass Notification Systems as described in UL 2572 2nd Edition and UL 864 10th Edition.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent signaling line circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 (expandable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable device capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,110 (SK) or 635 (SD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevices per built-in SLC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e159 SK detectors and 159 SK modules, or 127 SD protocol devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 (expandable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSBUS devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 (16 annunciators, 8 LED modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLOC units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable amplifiers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 (1000 total watts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorded messages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 recordable one-minute messages, mappable to eight EVS buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-frequency tone\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapable of producing 520 Hz tones to meet NFPA 72 requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz, 3.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlexput circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block provides connections for six Class B or three Class A NACs or auxiliary power; power-limited, supervised circuitry. Maximum current per circuit 3 A, and cannot exceed 6 A total for all circuits. End-of-line resistor 4.7k ohm, ½ watt for Class B NACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupervised and power-limited, Class A or Class B, 32 VDC, 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay contact rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A @ 27.4 VDC (resistive), Form C — two programmable relays and one fixed trouble relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCabinet holds a maximum of two 18 AH batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery charger capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 to 35 AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.6\" W x 28.1\" H x 5.1\" D (54.9 cm x 71.4 cm x 13.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 lbs. (22.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification cadence patterns\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 preset patterns, including ANSI 3.41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets NFPA requirements for operation at 0 to 49°C (32 to 120°F) and 93% ± 2% RH non-condensing at 32°C ± 2°C (90°F ± 3°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 864 10th Edition, UL 2572 2nd Edition; complies with NFPA 72, NFPA 13, NFPA 15, NFPA 16, NFPA 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed S2766; CSFM 7165-0559:0500; FDNY COA# 6249; FM Approved; Seismic (CA) VMA-45894-05C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eInstallation notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe 6 A Flexput cap is a total, not per circuit:\u003c\/strong\u003e each of the six Flexput circuits is rated 3 A maximum, but all circuits together cannot exceed 6 A. Budget notification load against the 6 A ceiling, not against six times 3 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmplifier wattage is a separate budget:\u003c\/strong\u003e the panel supports eight addressable amplifiers totalling 1000 watts. Speaker circuit load is sized against that figure, independently of the Flexput NAC current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass A halves the NAC count:\u003c\/strong\u003e the same terminal block yields either six Class B NACs or three Class A NACs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSK and SD devices cannot be mixed\u003c\/strong\u003e in the same fire alarm system, and the ceiling differs sharply — 1,110 SK points against 635 SD points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame point capacity as the 6820, larger cabinet:\u003c\/strong\u003e the EVS variant matches the 6820 on SLC capacity, Flexput ratings and battery limits, but the enclosure grows to 21.6\" x 28.1\" x 5.1\" and 50 lbs to house the voice components. Confirm wall space and mounting before ordering as a swap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity is limited by the cabinet:\u003c\/strong\u003e the charger handles 7 to 35 AH, but the cabinet holds only two 18 AH batteries. Larger standby calculations need the RBB remote battery box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended ambient is narrower than the listed range:\u003c\/strong\u003e although the system meets NFPA requirements to 120°F, Honeywell recommends a normal room temperature of 15 to 27°C (60 to 80°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMessage priority is programmable:\u003c\/strong\u003e the system can be configured to select EVS messages as priority over fire — confirm the intended sequence with the AHJ.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRelated models\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6820\u003c\/strong\u003e — the same addressable fire platform without the emergency voice system, in a smaller 16.4\" x 26.4\" x 4.1\" cabinet at 32 lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5820XL-EVS\u003c\/strong\u003e — the previous-generation panel the 6820EVS directly replaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEVS-50W \/ EVS-125W \/ EVS-100W\u003c\/strong\u003e — 50 watt, 125 watt and 50\/100 watt amplifiers; \u003cstrong\u003eEVS-INT50W\u003c\/strong\u003e internal 50 watt amplifier; \u003cstrong\u003eEVS-100WBU\u003c\/strong\u003e external backup amplifier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEVS-LOC\u003c\/strong\u003e — local operator console, up to four supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEVS-CE4\u003c\/strong\u003e — provides 4 additional audio circuits; \u003cstrong\u003eEVS-SW24\u003c\/strong\u003e 24 switch expander\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEVS-RVM\u003c\/strong\u003e — remote voice module; \u003cstrong\u003eEVS-VCM\u003c\/strong\u003e network voice control module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6815\u003c\/strong\u003e — SLC expander for SK devices; \u003cstrong\u003e5815XL\u003c\/strong\u003e — SLC expander for SD devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6860 \/ 6855 \/ 5860 \/ 5860R\u003c\/strong\u003e — LCD remote fire annunciators\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eSpecifications taken from the Honeywell Silent Knight data sheet \"6820EVS Intelligent Fire Alarm Control Panel with Emergency Voice System,\" document 351606:E (3\/7\/2022). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Silent Knight","offers":[{"title":"Default Title","offer_id":43702855893216,"sku":"6820EVS","price":4249.3,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/silent-knight-control-panels-default-title-silent-knight-6820evs-1110-point-addressable-fire-alarm-control-panel-31896989040864.jpg?v=1763281495"},{"product_id":"system-sensor-pdrp-2001e-fire-alarm-control-panel-220-240-vac","title":"System Sensor PDRP-2001E Fire Alarm Control Panel 220\/240 VAC","description":"\u003ch2\u003eSystem Sensor PDRP-2001E Fire Alarm Control Panel 220\/240 VAC\u003c\/h2\u003e","brand":"System Sensor","offers":[{"title":"Default Title","offer_id":43737834094816,"sku":"PDRP-2001E","price":1910.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/system-sensor-control-panels-default-title-system-sensor-pdrp-2001e-fire-alarm-control-panel-220-240-vac-35322184499424.jpg?v=1763281586"},{"product_id":"edwards-qs1-1-g-2-single-loop-system-gray-enclosure","title":"Edwards QS1-1-G-2 Single Loop System Gray Enclosure","description":"\u003ch2\u003eEdwards QS1-1-G-2 Single Loop System, Gray Enclosure, 230V Transformer\u003c\/h2\u003e\n\u003cp\u003eEdwards QS1-1-G-2 life safety control panel brings big-system intelligent control to small applications. Designed for easy setup and simple installation, QuickStart lives up to its name in every respect. QS1’s exclusive QuickStart auto-learn function, and the option of configuring the panel using convenient front panel programming or from a PC, makes short work of system setup.\u003c\/p\u003e\n\u003cp\u003eDevices come on-line in no time as well, thanks to QS1’s built-in barcode scanner port. A simple pass of the optional scanner is all it takes to store device information in the QuickStart database. The scanner can also be used for quick and easy text entry when assembling custom messages.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":43766697558240,"sku":"QS1-1-G-2","price":259.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/edwards-fire-alarms-default-title-edwards-qs1-1-g-2-single-loop-system-gray-enclosure-31896765071584.jpg?v=1763282230"},{"product_id":"edwards-qsa-1-s-intelligent-single-loop-life-safety-control-panel","title":"Edwards QSA-1-S Intelligent Single Loop Life Safety Control Panel","description":"\u003ch2\u003eEdwards QSA-1-S Intelligent Single Loop Life Safety Control Panel\u003c\/h2\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":43766697591008,"sku":"QSA-1-S","price":50.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/edwards-control-panels-default-title-edwards-qsa-1-s-intelligent-single-loop-life-safety-control-panel-31896764416224.jpg?v=1763282255"},{"product_id":"system-sensor-pdrp-2001-six-zone-24-volt","title":"System Sensor PDRP-2001 Six-Zone, 24-Volt","description":"\u003ch2\u003eSystem Sensor PDRP-2001 Six-Zone, 24-Volt deluge-preaction control panel (includes backbox, power supply, technical manual, and a frame-and-post operating instruction sheet) for single- and dual-hazard deluge and preaction applications\u003c\/h2\u003e","brand":"System Sensor","offers":[{"title":"Default Title","offer_id":43769815662816,"sku":"PDRP-2001","price":1831.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/system-sensor-control-panels-default-title-system-sensor-pdrp-2001-six-zone-24-volt-35322151633120.jpg?v=1763282448"},{"product_id":"edwards-3x-sfs1r-facp-complete-system-with-user-interface","title":"Edwards 3X-SFS1R FACP Complete System with User Interface","description":"\u003ch2\u003eEdwards 3X-SFS1R FACP Complete System with User Interface, CPU, 1 Loop W\/ 2Nd Loop Expansion, 3 Option Card Slots, 4 Class B Nacft.S, Universal 110\/220V 10 Amp Power Supply, Red Door, English, Order 3-SDC1 for Second Loop\u003c\/h2\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":43777816821984,"sku":"3X-SFS1R","price":3111.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/edwards-control-panels-default-title-edwards-3x-sfs1r-facp-complete-system-with-user-interface-31896710349024.jpg?v=1763282587"},{"product_id":"simplex-4007-9101","title":"Simplex 4007-9101 4007ES Hybrid Fire Alarm Control Panel, Four Conventional NACs, Red","description":"\u003cp\u003e\u003cstrong\u003eSimplex 4007-9101\u003c\/strong\u003e — 4007ES Hybrid fire detection and control unit, red cabinet, with one addressable SLC and four conventional notification appliance circuits.\u003c\/p\u003e\u003cp\u003eHybrid refers to initiation: the panel takes addressable devices on its IDNet 2 channel and conventional two-wire zones on plug-in zone\/relay modules, while driving non-addressable horns and strobes. That mix moves a conventional building onto an addressable head end without rewiring.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIDNet 2 SLC, 100 addressable points, expandable to 250 with two 4007-9803 modules\u003c\/li\u003e\n\u003cli\u003eFour NACs, each selectable Class A or Class B, 6 A total output power\u003c\/li\u003e\n\u003cli\u003eInput 120 VAC, 2 A maximum at 102 to 132 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eShips with one 4007-9801 eight-point zone\/relay module; four maximum\u003c\/li\u003e\n\u003cli\u003e4.3 in. color touchscreen; battery charging 6.2 Ah through 33 Ah\u003c\/li\u003e\n\u003cli\u003e145 mA supervisory, 190 mA alarm; 32°F to 120°F; NEMA 1 and IP30\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe 4007-9102 is the same unit in a platinum cabinet, and 4007-9101BA marks a USA-assembled build, not a different panel. The 4007ES panels on data sheet S4007-0002 use addressable notification instead of these conventional NACs.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":43777816985824,"sku":"4007-9101","price":1613.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/simplex-power-supplies-default-title-simplex-4007-9101-31897028296928.webp?v=1763282599"},{"product_id":"simplex-4009-9201-idnet-nac-extender","title":"Simplex 4009-9201 IDNet NAC Extender","description":"\u003cp\u003e\u003cstrong\u003eSimplex 4009-9201\u003c\/strong\u003e — a 120 VAC 4009 IDNet NAC Extender: a self-contained adjunct panel with four Class B notification appliance circuits and an 8 A power supply and battery charger.\u003c\/p\u003e\n\u003cp\u003eMeeting ADA notification requirements often needs more appliance power than the fire alarm control panel itself can deliver. The 4009 IDNet NAC Extender supplies up to 8 A across up to eight supervised reverse-polarity NACs, and it can be mounted next to the host panel or placed remotely for convenient power distribution. It accepts two quite different forms of control. Over IDNet addressable communications from a 4007ES, 4010, 4010ES, 4100ES or 4100U, each output NAC can be individually controlled for general alarm or selective area notification while consuming only a single point address per extender, and troubles are reported back in detail — including support for IDNet device-level earth fault location. Alternatively it can be driven directly from one or two conventional 24 VDC NACs, which is the retrofit path when an existing circuit simply needs more power. Either way the extender supervises itself and each output NAC for troubles including earth faults, and WALKTEST is available with both input choices. Output NACs can also be selected to provide Simplex strobe synchronization or to run TrueAlert non-addressable appliances in SmartSync two-wire mode.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4009-9201, 120 VAC input, four Class B NACs, 8 A power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A at 102 to 132 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal output rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 A for Special Application appliances; 6 A for Regulated 24 DC appliance power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard NACs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour, Class B, 2 A each, Special Application or Regulated 24 DC appliance power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional NACs (4009-9807)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour additional Class B, 1.5 A each Special Application; 1 A each Regulated 24 DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA at 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrobe synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 33 strobes per NAC can be synchronized; output NACs configured for Simplex synchronized strobe operation are synchronized to each other\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardwire control input requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConventional reverse polarity operation, 5 mA maximum, 16 to 33 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel supervisory current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 mA (basic panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel alarm current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mA (basic panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery charging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal batteries up to 12.7 Ah, or up to 18 Ah in the 4009-9801 external cabinet; two 12 VDC batteries required for 24 VDC operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIDNet channel loading\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to ten extenders per 4007ES, 4010ES, 4100ES or 4100U IDNet channel; up to five on the 4010 channel; one point address per extender\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH from 32°F to 104°F (0°C to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal blocks for 18 AWG stranded to 12 AWG solid (0.82 mm² to 3.31 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-1\/4 in. W x 13-1\/2 in. H (413 mm x 343 mm), 4-1\/4 in. (108 mm) deep, with a 5\/8 in. (16 mm) thick door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeismic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeismic tested and certified to IBC and CBC standards and to ASCE 7 categories A through F; requires battery brackets per data sheet S2081-0019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL listed to Standard 864; ULC listed model is 4009-9202CA; FM approved; CSFM Listing 7300-0026:214; MEA (NYC) acceptance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHost software revisions:\u003c\/strong\u003e the 4100U requires revision 11 software or higher and the 4010 requires revision 2 software or higher for compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardwire input mapping:\u003c\/strong\u003e with conventional NAC control the input-to-output mapping is selectable — NAC 1 to outputs 1 \u0026amp; 2 and 5 \u0026amp; 6 with NAC 2 to 3 \u0026amp; 4 and 7 \u0026amp; 8; or NAC 1 to outputs 1-4 with NAC 2 to 5-8; or NAC 1 to all outputs 1-8.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo inputs for split control:\u003c\/strong\u003e separate audible and visible output control, or SmartSync output operation, requires two input NACs. NAC 1 is on-until-reset and NAC 2 is on-until-silenced. In SmartSync mode NAC 1 is strobe control and NAC 2 is horn control for all outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConventional versus SmartSync is per-NAC only under IDNet:\u003c\/strong\u003e with IDNet control each output NAC can be individually set to conventional or SmartSync operation. With hardwire NAC input control, all output NACs must be one or the other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynchronizing several extenders:\u003c\/strong\u003e to synchronize strobe flash across up to four extenders, feed them from a Synchronized Flash Module (4905-9914 Class B, 4905-9922 Class A) or from a NAC selected for synchronized strobe output. Do not use a NAC selected for SmartSync operation for this.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal coding:\u003c\/strong\u003e each NAC input can be selected to track the input or to generate a local code. Local coding gives Temporal or 60 beats\/min March Time output, one code selection per extender, and the input NACs must be continuous on with alarm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass A costs slots:\u003c\/strong\u003e Class A operation in either mode requires the 4009-9808 dual Class A adapter, four maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIDNet repeating is once only:\u003c\/strong\u003e repeated communications can pass through only one series-connected repeater or fiber optic receiver, carrying up to 100 devices on the repeater output within a 250-device channel total, at up to 2,500 ft (762 m) to the farthest device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrouble behavior on conventional control:\u003c\/strong\u003e an extender wired to a conventional NAC signals trouble by opening the path to the NAC end-of-line resistor while retaining the ability to respond to a reverse-polarity alarm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit entry:\u003c\/strong\u003e the recommended conduit entrance varies with module selection — check installation instructions 574-181 and field wiring diagram 842-068 before drilling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4009-9301\u003c\/strong\u003e — the same extender with 240 VAC input, rated 1.5 A at 204 to 264 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4009-9202CA\u003c\/strong\u003e — the ULC listed version for Canada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4009-9807\u003c\/strong\u003e — additional four-point Class B NAC module, one maximum, 40 mA supervisory and alarm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4009-9808\u003c\/strong\u003e — dual Class A adapter covering two NAC outputs, four maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4009-9809 \/ 4009-9810 \/ 4009-9811\u003c\/strong\u003e — IDNet repeater (Class A or B), Class B fiber optic receiver, and Class A\/Class X fiber optic receiver\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4009-9801\u003c\/strong\u003e — external battery cabinet for up to 18 Ah batteries, 16-1\/4 in. W x 13-1\/2 in. H x 5-3\/4 in. D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4009-9805\u003c\/strong\u003e — red appliqué for the door; 2975-9801 \/ 2975-9802 semi-flush trim kits in beige and red\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the Simplex data sheet \"LifeAlarm Fire Alarm Controls — 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs,\" document S4009-0002-14 (9\/2015). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":43777817903328,"sku":"4009-9201","price":902.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/simplex-control-panels-default-title-simplex-4009-9201-idnet-nac-extender-32594326290656.jpg?v=1763282631"},{"product_id":"simplex-4100-2302-8-slot-exp-bay-filler-panel","title":"Simplex 4100-2302 8 Slot Exp Bay Filler Panel","description":"\u003cp\u003e\u003cstrong\u003eSimplex 4100-2302\u003c\/strong\u003e — blank filler panel that closes an unused bay opening in a 4100U or 4100ES dress panel.\u003c\/p\u003e\u003cp\u003eCabinets get ordered with more bay openings than the job ends up populating, and a retrofit that pulls a bay of modules leaves the same open rectangle in the front of the panel. The filler panel closes it, mounting behind the dress panel so the finished face stays continuous. It suits any opening in a one, two or three bay dress panel, which makes it a sensible shelf item for anyone servicing 4100U and 4100ES equipment.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCovers a bay opening in a Simplex 4100U or 4100ES dress panel\u003c\/li\u003e\n\u003cli\u003eAttaches to the inside of the dress panel with four supplied flange nuts\u003c\/li\u003e\n\u003cli\u003eInstalls notches down, textured side facing out\u003c\/li\u003e\n\u003cli\u003eCovered by Simplex installation instruction 579-877\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis is sheet-metal trim for the dress panel, not a blank module for a card slot, and it adds no electrical function. Confirm the cabinet is a 4100U or 4100ES before ordering.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":43777824522464,"sku":"4100-2302","price":29.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/simplex-control-panels-default-title-simplex-4100-2302-8-slot-exp-bay-filler-panel-34337995784416.jpg?v=1763282716"},{"product_id":"simplex-4100-9311","title":"Simplex 4100-9311 EPS Master Controller 120V","description":"\u003cp\u003eEps Master Controller 120V\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":43777830027488,"sku":"4100-9311","price":3145.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/simplex-fire-alarms-default-title-simplex-4100-9311-31897078300896.jpg?v=1763282813"},{"product_id":"edwards-fsp1004g-conventional-fire-alarm-control-panel-gray","title":"Edwards FSP1004G FireShield Plus 10-Zone Conventional Fire Alarm Control Panel, Gray Cabinet","description":"\u003cp\u003e\u003cstrong\u003eEdwards FSP1004G\u003c\/strong\u003e — FireShield Plus conventional fire alarm control panel with ten initiating circuits, in the gray cabinet.\u003c\/p\u003e\u003cp\u003eDespite the 1004 in the catalog number this is a ten zone panel: the digits read as ten IDCs and four NACs. It is the larger FireShield Plus panel and the only one whose supply can be expanded. Circuits are paired rather than fixed, so two Class B IDCs can be combined into one Class A IDC.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e10 Class B IDCs and 4 Class B NACs as shipped; up to 5 Class A IDCs or 2 Class A NACs\u003c\/li\u003e\n\u003cli\u003e4.25 A power supply, expandable to 7.5 A with the F-XTR120 transformer\u003c\/li\u003e\n\u003cli\u003eNACs rated 2.0 A each, 3.5 A total, or 7.0 A with the expander\u003c\/li\u003e\n\u003cli\u003eAuxiliary output 24 Vdc regulated, 0.5 A maximum\u003c\/li\u003e\n\u003cli\u003eCharges up to two 24 Ah sealed lead acid batteries, 18 Ah fitting in the cabinet\u003c\/li\u003e\n\u003cli\u003eNAC modes: Genesis, continuous, temporal, coded and city tie\u003c\/li\u003e\n\u003cli\u003eTerminals 18 to 12 AWG; UL 864 under S3000, ULC-S527, CSFM and FDNY\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe G is cabinet color only. FSP1004R is the same panel in red, FSP1004GD and FSP1004RD ship with the DACT dialer fitted, and FSP1004-2 is the 230 Vac build. FSP502 is the five zone, two NAC panel.\u003c\/p\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":43777862205664,"sku":"FSP1004G","price":759.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/edwards-control-panels-default-title-edwards-fsp1004g-conventional-fire-alarm-control-panel-gray-31896736071904.jpg?v=1763283146"},{"product_id":"edwards-fsp1004gd-conventional-fire-alarm-control-panel-gray-120v","title":"Edwards FSP1004GD FireShield Plus Conventional Fire Alarm Control Panel, 10 Zone, 4 NAC, Built-in Dialer, Gray, 120V","description":"\u003cp\u003e\u003cstrong\u003eEdwards FSP1004GD\u003c\/strong\u003e — FireShield Plus ten-zone conventional fire alarm control panel, 120 V, gray cabinet, supplied with the F-series dialer and modem.\u003c\/p\u003e\u003cp\u003eFireShield Plus covers small and medium buildings, with front-panel programming and one-person walk test. Each initiating circuit is selectable for alarm, alarm with smoke verification, waterflow with or without retard, combination waterflow and supervisory, latching supervisory or monitor. The trailing D denotes the factory-fitted F-DACT communicator, which reports to a central station over loop-start telephone lines and adds an LCD, an event history log and a modem.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTen Class B initiating device circuits; pairs convert to give up to five Class A\u003c\/li\u003e\n\u003cli\u003eFour Class B notification circuits, or two Class A\u003c\/li\u003e\n\u003cli\u003e2.0 A per NAC, 3.5 A total, 7.0 A with the F-XTR120 expander transformer\u003c\/li\u003e\n\u003cli\u003e4.25 A supply expandable to 7.5 A; 0.5 A 24 VDC auxiliary\u003c\/li\u003e\n\u003cli\u003eTwo 18 Ah sealed lead-acid batteries fit the cabinet\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eCheck the suffix: FSP1004G is the same ten-zone panel without the dialer, FSP1004RD is the red-cabinet version with it, and FSP1004G-2 is the 230 V model.\u003c\/p\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":43777862238432,"sku":"FSP1004GD","price":824.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/edwards-control-panels-default-title-edwards-fsp1004gd-conventional-fire-alarm-control-panel-gray-120v-31896735842528.jpg?v=1763283123"},{"product_id":"edwards-fsp502g-conventional-fire-alarm-control-panel","title":"Edwards FSP502G FireShield Plus 5-Zone Conventional Fire Alarm Control Panel, Gray Cabinet, 120 Vac","description":"\u003cp\u003e\u003cstrong\u003eEdwards FSP502G\u003c\/strong\u003e — FireShield Plus conventional fire alarm control panel with five Class B initiating device circuits and two Class B notification appliance circuits, in a gray cabinet.\u003c\/p\u003e\u003cp\u003eThe part number decodes from the ordering table: the 5 is the IDC count, the 02 the NAC count, and the trailing G selects the gray cabinet. No trailing D means no factory-installed DACT dialer. Pairs of on-board IDCs or NACs convert in the field to single Class A circuits, so the panel runs as five, three or one Class B IDC.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFive Class B IDCs; up to two Class A IDCs by pairing\u003c\/li\u003e\n\u003cli\u003eTwo Class B NACs, convertible to one Class A NAC\u003c\/li\u003e\n\u003cli\u003ePower supply 4.25 A total: 3.5 A notification, 0.5 A auxiliary at 24 Vdc\u003c\/li\u003e\n\u003cli\u003eNAC rating 2.0 A each, 3.5 A total, 24 Vfwr\u003c\/li\u003e\n\u003cli\u003eAC input 120 Vac 60 Hz at 1.25 A; standby 104 mA, alarm 224 mA\u003c\/li\u003e\n\u003cli\u003eBatteries to 24 Ah sealed lead acid, 10 Ah maximum in the cabinet\u003c\/li\u003e\n\u003cli\u003eUL 864, ULC-S527, CSFM and FDNY listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eConfirm the suffix before ordering: FSP502R is the same panel in red, FSP502GD and FSP502RD add the factory dialer, FSP502-2 is the 230 Vac version, and FSP302G drops to three IDCs.\u003c\/p\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":43777862336736,"sku":"FSP502G","price":424.85,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/edwards-control-panels-default-title-edwards-fsp502g-conventional-fire-alarm-control-panel-34518548021472.jpg?v=1763283121"},{"product_id":"edwards-io1000g-fire-alarm-control-panel-1-loop-grey","title":"Edwards IO1000G Fire Alarm Control Panel 1-Loop Grey","description":"\u003ch2\u003eEdwards IO1000G Fire Alarm Control Panel 1-Loop 125\/Det, Mod, Grey\u003c\/h2\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":43777865744608,"sku":"IO1000G","price":1250.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/edwards-control-panels-default-title-edwards-io1000g-fire-alarm-control-panel-1-loop-grey-32276175618272.jpg?v=1763283249"},{"product_id":"edwards-io1000g-2-four-loop-system-250-point-230v","title":"Edwards IO1000G-2 Four Loop System 250-Point 230V","description":"\u003ch2\u003eEdwards IO1000G-2 Four Loop System with One 250-Point Loop Installed, 230V, Gray Door\u003c\/h2\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":43777866432736,"sku":"IO1000G-2","price":1137.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/edwards-control-panels-default-title-edwards-io1000g-2-four-loop-system-250-point-230v-36505483509984.webp?v=1763283194"},{"product_id":"edwards-io64g","title":"Edwards IO64G Fire Alarm Control Panel, 1 Loop, 64 Intelligent Devices","description":"\u003ch2\u003eEdwards IO64G Fire Alarm Control Panel, 1 Loop, 64 Intelligent Devices Max, 2 Class B Nacft.S, 4.25A Power Supply, Gray Door, 115Vac, Capacity For Up (2) 10A\/H Batteries, English\u003c\/h2\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":43777866563808,"sku":"IO64G","price":1053.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/edwards-control-panels-default-title-edwards-io64g-34518670639328.jpg?v=1763283226"},{"product_id":"edwards-io64r-fire-alarm-control-panel-1-loop-115vac","title":"Edwards IO64R Fire Alarm Control Panel 1 Loop 115VAC","description":"\u003ch2\u003eEdwards IO64R Fire Alarm Control Panel 1 Loop, 64 Intelligent Devices Max, 2 Class B Nacft.S, 4.25A Power Supply, Red Door, 115Vac, Capacity for up (2) 10A\/H Batteries, English\u003c\/h2\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":43777866694880,"sku":"IO64R","price":1065.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/edwards-control-panels-default-title-edwards-io64r-fire-alarm-control-panel-1-loop-115vac-34518670803168.jpg?v=1763283210"},{"product_id":"protectwell-ptw-nca-sc-assy","title":"Protectwell PTW-NCA-SC Assembly, FNL, Ptwnca, Simp Chinese","description":"\u003ch2\u003eProtectwell PTW-NCA-SC Assy, Fnl, Ptw-Nca, Simp Chinese\u003c\/h2\u003e","brand":"Protectwell","offers":[{"title":"Default Title","offer_id":43790993391840,"sku":"PTW-NCA-SC","price":606.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/protectwell-fire-alarms-default-title-protectwell-ptw-nca-sc-assy-31896938610912.jpg?v=1763283456"},{"product_id":"napco-gemc-24vr-add-on-24v-regulator","title":"Napco GEMC-24VR Add on 24V Regulator","description":"\u003ch2\u003eThe 24V Regulator is intended to provide a constant 24V regulated output (maximum current 1.0A) from the Gemini C-Series control panel motherboards or the GEMC-NAC7L\/S Supervised NAC Extender\u003c\/h2\u003e\n\u003cp\u003eTo provide this 24V regulated output, one of the four special application NAC outputs must be dedicated and programmed as \"Reverse Polarity\" and not programmed to activate on any alarms or events.\u003c\/p\u003e","brand":"Napco","offers":[{"title":"Default Title","offer_id":43847538082016,"sku":"GEMC-24VR","price":58.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/napco-fire-alarms-default-title-napco-gemc-24vr-add-on-24v-regulator-36706119942368.jpg?v=1763283586"},{"product_id":"fire-lite-es-50xp-addressable-fire-alarm-control-panel","title":"Fire-Lite ES-50XP Addressable Fire Alarm Control Panel","description":"\u003cp\u003e\u003cstrong\u003eFire-Lite ES-50XP\u003c\/strong\u003e — an intelligent addressable fire alarm control panel with a single SLC supporting up to 50 addressable devices in any combination of detectors or modules, supplied with an integrated CLSS Pathway Pro dual-SIM (AT\u0026amp;T\/Verizon) 5G LTE-M communicator.\u003c\/p\u003e\n\u003cp\u003eThe ES-50X, ES-50XC, ES-50XI and ES-50XP are the latest intelligent addressable fire alarm control panels from Fire•Lite Alarms and are direct replacements for the MS-9050UD. The ES-50X Series programs just like Fire•Lite’s other addressable panels, yet fits into applications previously served only by conventional panels. The ES-50XP features an integrated CLSS Pathway Pro Communicator, which transmits system status — alarms, troubles, AC loss and the like — to the central station using LTE CAT-M1 networks, serving as a bridge between the fire system and the CLSS Cloud, with an optional IP connection for backup communication. As an integrated communicator, the CLSS Pathway Pro can typically transmit data faster than dial capture methods, and it enables Honeywell’s Connected Life Safety Services cloud solutions for site monitoring and test-and-inspection reporting. Remote and local programming is possible using the FS-Tools upload\/download utility, and the USB port also allows download or upload of the entire program, history file, walk-test data, current status and system voltages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a quick-install chassis and housed in a metal cabinet.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eES-50XP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent Signaling Line Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable device capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 (any combination of detectors and modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnnunciators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (up to 8 per ANN-BUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiteSpeed and CLIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC wire run\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC wiring class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets NFPA Class B and Class A requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification appliance circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo independently programmable circuits, configurable Class A or Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A special application, 250 mA regulated, per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal 24 VDC system power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 A maximum, shared between all NAC circuits and the ANN-BUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC end-of-line resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7k ohm, ½ watt (P\/N 71252) for Class B; system capable of 1.9kΩ – 22kΩ ELR range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo programmable Form-C relays plus one fixed trouble relay; 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 or 240 VAC, 50\/60 Hz, 3.25 A, auto-sensing (no switch required); minimum 14 AWG with 600 V insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 12 V 18 AH lead-acid batteries; charger capacity 7–18 AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated CLSS Pathway Pro; dual SIM AT\u0026amp;T\/Verizon, LTE CAT-M1 5G, with optional IP connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral 80-character LCD with backlighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDoor 19.26″ H × 16.82″ W × 0.72″ D; backbox 19.00″ H × 16.65″ W × 5.25″ D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.9 lbs. (12.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature and humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–120°F (0–49°C); 93% ±2% RH non-condensing at 90°F ±3°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eListed to UL Standard 864, 10th edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency listings (ES-50XP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETL 5017286; CSFM 7165-0075:0511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo NACs, not four:\u003c\/strong\u003e the ES-50X Series provides two independently programmable built-in notification appliance circuits, each configurable for Class A or Class B with no optional card required. Design NAC layouts around two circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower budget:\u003c\/strong\u003e each NAC is rated 2.5 A special application \/ 250 mA regulated, but the maximum total 24 VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A. Size the whole system to that ceiling, not to the per-circuit rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery sizing:\u003c\/strong\u003e the cabinet holds a maximum of two 18 AH batteries and the onboard charger covers 7–18 AH. A CHG-75 or CHG-120F external charger is required for batteries larger than 18 AH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicator differences:\u003c\/strong\u003e the pre-installed IPOTS-COM Ethernet\/POTS communicator is fitted to the ES-50X and ES-50XC only. The ES-50XP instead carries the integrated CLSS Pathway Pro cellular communicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e databases upload and download via the panel’s USB port with FS-Tools; offline programming requires an Ethernet connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy device caution:\u003c\/strong\u003e legacy 300 Series devices such as the CP300\/CP350, SD300(T)\/SD350(T) and older modules including the M300, M301, M302, C304 and BG-10LX are not compatible with LiteSpeed polling. If the SLC contains one of these, polling must be set to standard CLIP protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSLC wiring:\u003c\/strong\u003e shielded wire is not required, but all SLC wiring should be twisted-pair to minimise the effects of electrical interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-50X\u003c\/strong\u003e — same 50-point panel with a pre-installed IPOTS-COM dual technology (POTS and IP) communicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-50XC\u003c\/strong\u003e — as ES-50X, supplied with a dress panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-50XI\u003c\/strong\u003e — 50-point panel supplied without a communicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-200X Series\u003c\/strong\u003e — higher-capacity panels in the same ES family (see data sheet DF-60957)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANN-80 \/ ANN-100\u003c\/strong\u003e — remote LCD annunciators that mimic the FACP display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4XTMF\u003c\/strong\u003e — reverse polarity transmitter module, required for auxiliary and reverse-polarity signalling applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the Fire•Lite Alarms data sheet “ES-50X Series Intelligent Addressable Fire Alarm Control Panels,” document DF-60953:D (3\/27\/2023). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":44077597851872,"sku":"ES-50XP","price":946.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/fire-lite-control-panels-default-title-fire-lite-es-50xp-addressable-fire-alarm-control-panel-32009163014368.jpg?v=1763283664"},{"product_id":"fire-lite-es-200xp-addressable-fire-alarm-control-panel","title":"Fire-Lite ES-200XP Addressable Fire Alarm Control Panel","description":"\u003cp\u003e\u003cstrong\u003eES-200XP\u003c\/strong\u003e — intelligent addressable fire alarm control panel with one signaling line circuit, 198-point capacity and an integrated CLSS Pathway Pro dual-SIM 5G LTE-M cellular communicator.\u003c\/p\u003e\n\u003cp\u003eThe ES-200X Series is a direct replacement for the MS-9200UDLS and programs just like Fire•Lite’s other addressable products. What sets the ES-200XP apart within the series is its communicator: an integrated CLSS Pathway Pro, a dual-SIM (AT\u0026amp;T\/Verizon) 5G LTE-M communicator with optional IP connection. It transmits system status — alarms, troubles, AC loss and so on — to the central station over LTE CAT-M1 networks and serves as a bridge between the fire system and the CLSS Cloud, enabling cloud monitoring through Honeywell’s Connected Life Safety Services. As an integrated communicator it can typically transmit data faster than dial capture methods, and the IP communicator’s Internet monitoring capability meets requirements for backup communication. The single SLC (DCL) loop carries up to 198 addressable devices (99 detectors and 99 modules) and four independently programmable NACs can each be configured Class A or Class B. The ES-200XP ships as the main circuit board with display, pre-installed CLSS Pathway Pro communicator, chassis with transformer, dress panel, backbox with door, and a plastic bag containing screws, cables and key.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated CLSS Pathway Pro; dual-SIM (AT\u0026amp;T\/Verizon) 5G LTE-M, LTE CAT-M1, with optional IP connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent signaling line circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; meets NFPA Class B and Class A requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable device capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e198 (99 addressable detectors and 99 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnnunciators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (up to 8 per ANN-BUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiteSpeed and CLIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC wire run\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 ft. (3,000 m) in LiteSpeed mode, twisted unshielded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification appliance circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block provides connections for four NACs, Class B or Class A; special application power; power-limited, supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum signaling current per NAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A special application; 250 mA regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal 24 VDC system power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 A maximum, shared between all NAC circuits and the ANN-BUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC end-of-line resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7k ohm, ½ watt (P\/N 71252 UL listed) for Class B NAC; system capable of 1.9k–22k ohm ELR range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo programmable Form-C relays and one fixed trouble relay; 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive); non-power-limited, non-supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 or 240 VAC, 50\/60 Hz, 3.25 A, auto-sensing (no switch required); minimum 14 AWG (2.00 mm²) with 600 V insulation; non-power-limited, supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 12 V 18 AH lead-acid; charger capacity 7–18 AH; cabinet holds a maximum of two 18 AH batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral 80-character LCD with backlighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackbox\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.00\" (48.26 cm) H × 16.65\" (42.29 cm) W × 5.25\" (13.34 cm) D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.26\" (48.92 cm) H × 16.82\" (42.73 cm) W × 0.72\" (1.82 cm) D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.9 lbs. (12.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–49°C \/ 32–120°F, relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eListed to UL Standard 864, 10th edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeismic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIBC 2021, IBC 2018, IBC 2015, IBC 2012, IBC 2009; CBC 2019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency listings (ES-200XP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL: S624; ETL: 5017286; CSFM 7165-0075:0511; FDNY COA #2023-TMCOAP-002354-CERT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo IPOTS-COM on this model:\u003c\/strong\u003e the pre-installed IPOTS-COM and the optional AlarmNet cellular communicators are for the ES-200X and ES-200XC only. On the ES-200XP the communicator is the integrated CLSS Pathway Pro.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming path:\u003c\/strong\u003e ethernet upload\/download using the IPOTS-COM is an ES-200X \/ ES-200XC capability. Plan on the panel USB port and USB cable for uploading and downloading programming, history, walk-test data, current status and system voltages on the ES-200XP. Offline programming with FS-Tools requires an ethernet connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower budget:\u003c\/strong\u003e 2.5 A is the per-circuit maximum. Maximum or total 24 VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A — four circuits do not give you four times 2.5 A. The PWRMOD24 power expander module increases alarm power output to 6 amps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e the cabinet holds a maximum of two 18 AH batteries and the onboard charger covers 7–18 AH. Larger batteries require a CHG-75 or CHG-120F and an external BB-26 or BB-55F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeismic installations:\u003c\/strong\u003e use SEISKIT-COMMENC, which includes a battery bracket for two 7, 12 or 18 AH batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy devices:\u003c\/strong\u003e 300 Series devices such as CP300\/CP350, SD300(T)\/SD350(T), M300, M301, M302, C304 and BG-10LX are not compatible with LiteSpeed polling; if any are on the SLC, polling must be set to standard CLIP protocol.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-200X\u003c\/strong\u003e — pre-installed IPOTS-COM dual technology (POTS and IP) communicator instead of the CLSS Pathway Pro; no dress panel listed in the carton.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-200XC\u003c\/strong\u003e — pre-installed IPOTS-COM, dress panel included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eES-200XI\u003c\/strong\u003e — no communicator fitted; dress panel included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMS-9200UDLS\u003c\/strong\u003e — the legacy panel the ES-200X Series directly replaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the Fire•Lite Alarms data sheet \"ES-200X Series Intelligent Addressable Fire Alarm Control Panels,\" document DF-60957:F (5\/28\/2025). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":44077598441696,"sku":"ES-200XP","price":1310.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/fire-lite-control-panels-default-title-fire-lite-es-200xp-addressable-fire-alarm-control-panel-34338125971680.jpg?v=1763283692"},{"product_id":"potter-afc-50-fire-alarm-control-panel","title":"Potter AFC-50 Fire Alarm Control Panel","description":"\u003ch2\u003eThe AFC-50 is an analog\/addressable releasing fire alarm system with a total system capacity of 50 addresses\u003c\/h2\u003e\n\u003cp\u003eAdditional capacity on the system is achieved using multi-point SLC modules.\u003c\/p\u003e\n\u003cp\u003eThe control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC).\u003c\/p\u003e\n\u003ch2\u003eThe AFC-50 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input\/Output (I\/O) circuits.\u003c\/h2\u003e\n\u003cp\u003eThe NACs are rated at 3 Amps each and the I\/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing.\u003c\/p\u003e\n\u003cp\u003eThe strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper\/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The I\/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously.\u003cbr\u003e\u003cbr\u003eThe NACs may be expanded using the PSN-1000 series intelligent power supplies.\u003c\/p\u003e\n\u003ch2\u003eEach PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the AFC-50 will support up to 31 power supplies.\u003c\/h2\u003e\n\u003cp\u003eThe system will synchronize the strobes system wide. In addition, the PSN-1000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all circuit connections.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":44079440167136,"sku":"AFC-50","price":790.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/potter-control-panels-default-title-potter-afc-50-fire-alarm-control-panel-36338464063712.png?v=1763283671"},{"product_id":"notifier-nfs-320-intelligent-fire-alarm-control-panel","title":"Notifier NFS-320 Intelligent Fire Alarm Control Panel","description":"\u003cp\u003e\u003cstrong\u003eNOTIFIER NFS-320\u003c\/strong\u003e — an intelligent addressable fire alarm control panel in the ONYX® Series, with one isolated Signaling Line Circuit supporting up to 318 addressable devices.\u003c\/p\u003e\n\u003cp\u003eONYX Series products meet virtually every application requirement in stand-alone or network configurations. The NFS-320’s modular design makes system planning easier: the panel can be configured with just a few devices for small building applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. Wireless fire protection can be added with the SWIFT wireless gateway and devices.\u003c\/p\u003e\n\u003cp\u003eFor installations using NFS-320C, an optional ACM Series annunciator can be mounted in the same cabinet (up to 48 zones\/points, ordered separately; see DN-60085). ONYX® Series panels integrate with the Connected Life Safety Services (CLSS) platform through the CLSS Gateway, providing connectivity to central station, cloud and mobile applications (see HON-62034).\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote:\u003c\/em\u003e unless called out with a version-specific \"R\", \"C\" or \"E\" at the end of the part number, \"NFS-320\" refers to models NFS-320, NFS-320R, NFS-320C and NFS-320E.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertified for seismic applications when used with the appropriate seismic mounting kit.\u003c\/li\u003e\n\u003cli\u003eApproved for marine applications when used with listed compatible equipment. See DN-60688.\u003c\/li\u003e\n\u003cli\u003eOne isolated intelligent Signaling Line Circuit (SLC), Class A, B or X.\u003c\/li\u003e\n\u003cli\u003eWireless fire protection using SWIFT Smart Wireless Integrated Fire Technology. See DN-60820.\u003c\/li\u003e\n\u003cli\u003eUp to 159 detectors and 159 modules per SLC; 318 devices maximum. Polls up to 318 devices in less than two seconds.\u003c\/li\u003e\n\u003cli\u003eDetectors can be any mix of photo, thermal or multi-sensor; modules include addressable pull stations, normally-open contact devices, two-wire smoke detectors, notification or relay.\u003c\/li\u003e\n\u003cli\u003eStandard 80-character display and full QWERTY keypad.\u003c\/li\u003e\n\u003cli\u003eHigh-speed network for up to 200 nodes; standard network for up to 103 nodes.\u003c\/li\u003e\n\u003cli\u003e6.0 A power supply with four Class A\/B built-in Notification Appliance Circuits. Selectable System Sensor, Wheelock or Gentex strobe synchronization.\u003c\/li\u003e\n\u003cli\u003eBuilt-in Alarm, Trouble, Security and Supervisory relays.\u003c\/li\u003e\n\u003cli\u003eVeriFire® Tools online or offline programming utility — upload\/download, save, store, check, compare and simulate panel databases, and upgrade panel firmware.\u003c\/li\u003e\n\u003cli\u003eAutoprogramming and Walk Test reports.\u003c\/li\u003e\n\u003cli\u003eHistory file with 800-event capacity in nonvolatile memory, plus a separate 200-event alarm-only file.\u003c\/li\u003e\n\u003cli\u003eAlarm Verification selection per point with automatic counter; Presignal\/Positive Alarm Sequence (PAS).\u003c\/li\u003e\n\u003cli\u003eNAC coding: march time, temporal, California two-stage, Canadian two-stage, strobe synchronization.\u003c\/li\u003e\n\u003cli\u003eAutomatic time control functions with holiday exceptions; powerful Boolean logic equations.\u003c\/li\u003e\n\u003cli\u003eExtensive built-in transient protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent signaling line circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable monitor\/control modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable internal hardware and output circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecial programming zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLCD annunciators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eACS annunciators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 addresses x 64 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 50\/60 Hz, 5.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoard current draw (standby\/alarm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.250 A, plus 0.035 A for each NAC in use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal output 24 V power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.0 A in alarm, shared by all internal circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard notification circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour, 1.5 A each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResettable regulated 24 V power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-resettable regulated 24 V outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo — 1.25 A and 0.50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-resettable 5 V power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery charger range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 AH – 200 AH (use a separate cabinet for batteries over 26 AH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFloat rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackbox dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.12 in. (46.025 cm) wide x 18.12 in. (46.025 cm) high x 5.81 in. (14.76 cm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.187 in. (46.195 cm) wide x 18.40 in. (46.736 cm) high x 0.75 in. (1.905 cm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrim ring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolding width 0.905 in. (2.299 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight (without batteries)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.15 lb. (16.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSWIFT gateway capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach SWIFT Gateway supports up to 49 SWIFT devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–120°F (0–49°C), relative humidity 93% ± 2% non-condensing at 90°F ± 3°F (32°C ± 2°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 864 10th edition; UL 2610; UL 2572 (NFS-320 version 20 or higher); ULC-S527-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ULC listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCSFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7165-0028:0243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFDNY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOA# 6212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOther approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCity of Chicago\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeismic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIBC 2012, 2009, 2006, 2003, 2000; CBC 2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6.0 A is a shared pool:\u003c\/strong\u003e the power supply has a total of 6.0 A of available power shared by all internal circuits. Four NACs rated 1.5 A each sum past that — use the current draw calculation sheet in the Installation Manual rather than adding circuit maximums.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery size drives the cabinet:\u003c\/strong\u003e the charger covers 18–200 AH, but batteries over 26 AH require a separate cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine voltage is model-specific:\u003c\/strong\u003e the NFS-320 is a 120 VAC panel; the NFS-320E is the 220\/240 VAC, 2.5 A version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeismic certification requires the kit:\u003c\/strong\u003e use SEISKIT-320\/B26 for the panel; the BB-25 and NFS-LBB have their own kits (SEISKIT-BB25, SEISKIT-LBB).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary and remote station service\u003c\/strong\u003e per NFPA 72 requires the TM-4; CENTRAL STATION service requires a DACT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine approval is configuration-dependent:\u003c\/strong\u003e marine approved systems must be built from the components itemized in DN-7112, following installation document PN 54756. See DN-60688.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended room conditions:\u003c\/strong\u003e although the panel meets NFPA requirements across its full range, battery and component life are best at a normal room temperature of 60–80°F (15–27°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFS-320E\u003c\/strong\u003e — 220\/240 VAC, 50\/60 Hz, 2.5 A version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFS-320C\u003c\/strong\u003e — version allowing an optional ACM Series annunciator in the same cabinet (see DN-60085).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFS-320R\u003c\/strong\u003e — red-cabinet version of the panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFS-320SYS\u003c\/strong\u003e — system configuration of the panel (see DN-60637).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFS2-640\u003c\/strong\u003e — larger ONYX Series panel with one SLC expandable to two.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFWSG(A)\u003c\/strong\u003e — SWIFT wireless gateway, supporting up to 49 wireless devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the NOTIFIER data sheet \"NFS-320 Intelligent Addressable Fire Alarm Control Panel,\" document DN-7112:Q (9\/14\/2022). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":44262748061920,"sku":"NFS-320","price":2582.4,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/notifier-control-panels-default-title-notifier-nfs-320-intelligent-fire-alarm-control-panel-32082212126944.jpg?v=1769698556"},{"product_id":"notifier-cpu2-3030d","title":"Notifier CPU2-3030D NFS2-3030 Central Processing Unit with 640-Character Display and QWERTY Keypad","description":"\u003cp\u003e\u003cstrong\u003eNotifier CPU2-3030D\u003c\/strong\u003e — central processing unit for the NFS2-3030 addressable fire alarm panel, shipped with its 640-character keypad and display installed.\u003c\/p\u003e\u003cp\u003eThis is the board that runs the panel and the operator interface in one assembly, which is why data sheet DN-7070 lists it as the panel primary display. It is not an add-on annunciator.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBacklit LCD of 640 characters, 16 lines × 40 characters, with full QWERTY keypad\u003c\/li\u003e\n\u003cli\u003e11 LED indicators plus Acknowledge, Signal Silence, Drill, Reset and Lamp Test controls\u003c\/li\u003e\n\u003cli\u003eDrives 1 to 10 signaling line circuits and up to 3,180 devices per panel\u003c\/li\u003e\n\u003cli\u003eDraws 0.340 A; requires an AMPS-24(E) supply and one CHS-M3 chassis\u003c\/li\u003e\n\u003cli\u003eSupports 32 ACS annunciator addresses at 64 or 96 points each\u003c\/li\u003e\n\u003cli\u003eUL\/ULC listed S635, FM approved, FM6320 approved for gas detection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe direct sibling is the CPU2-3030ND, the same processor without a display, drawing 0.120 A. CPU2-3030DC is the English ULC version. Do not confuse the board with the DP-DISP, the dress panel that trims the top row once a CPU2-3030D is fitted.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":44262748389600,"sku":"CPU2-3030D","price":2020.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/notifier-display-default-title-notifier-cpu2-3030d-31925386379488.jpg?v=1763283728"},{"product_id":"notifier-ncd-network-control-display","title":"Notifier NCD Network Control Display","description":"\u003ch2\u003eThe Network Control Display (NCD) is the next generation of network control annunciators for the NOTI•FIRE•NET™ network\u003c\/h2\u003e\n\u003cp\u003eIts contemporary design meets today’s building aesthetics.\u003c\/p\u003e\n\u003cp\u003eThe intuitive 1024 x 600 10\" touch screen provides detailed color coded system status and point information. It is compatible with NOTIFIER INSPIRE™ and ONYX® series fire alarm control panels (FACP) and nodes such as the INSPIRE N16e\/x FACPs, ACM-30 annunciator and RLD remote display as well as the ONYX NFS2-3030, NFS2- 640, and NFS-320 FACPs.\u003c\/p\u003e\n\u003cp\u003eThe NCD provides system control and status\/history display capabilities for all, or for selected network nodes. It can also be used as the primary display for control and status capabilities on a displayless node via Direct Connect.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Full supervision of all inputs and network integrity.\u003cbr\u003e• High definition 10\" 1024 x 600 color touchscreen display.\u003cbr\u003e• LED status indicators for power and off normal\u003cbr\u003e• Requires 24 VDC, and a network connection or direct connect.\u003cbr\u003e• Three USB 2.0 connections, USB C, USB Micro, and USB A.\u003cbr\u003e• Trouble Relay.\u003cbr\u003e• Tamper and Trouble inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Device information, including point address and description, can be quickly identified.\u003cbr\u003e• Network-wide: Acknowledge, Silence, Reset.\u003cbr\u003e• Lamp Test.\u003cbr\u003e• Interactive Summary Event Count display and event handling.\u003cbr\u003e• Intuitive user guidance program.\u003cbr\u003e• Fully programmable node-mapping subsystem.\u003cbr\u003e• Up to 2000 programmable logic zones\u003cbr\u003e• Up to 32 custom action buttons\u003cbr\u003e• Environmental adjustment controls to maximize display legibility.\u003cbr\u003e• Color coded Icon based event notification.\u003cbr\u003e• Can be used as FACP primary display.\u003cbr\u003e• Supports standard and high speed network systems.\u003cbr\u003e• Event vectoring for quick viewing of event groups.\u003cbr\u003e• Virtual alphanumeric QWERTY keypad and numeric keypad displays when data input is needed.\u003cbr\u003e• Individual Enable\/Disable or group Enable\/Disable for networked\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eONYX and INSPIRE series panels.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Control ON\/OFF for networked ONYX and INSPIRE series panel control points.\u003cbr\u003e• Read Status networked ONYX and INSPIRE series panel points and zones.\u003cbr\u003e• History Buffer (10,000 events, 3000 displayed).\u003cbr\u003e• Up to 50 unique users and 5 different user levels.\u003cbr\u003e• Read Status from event display.\u003cbr\u003e• History filters for report displaying.\u003cbr\u003e• Timer control for Auto Silence, AC Fail Delay.\u003cbr\u003e• Custom wallpaper\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":44262748750048,"sku":"NCD","price":1705.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/notifier-control-panels-default-title-notifier-ncd-network-control-display-33440960807136.jpg?v=1763283722"},{"product_id":"notifier-nfw-100x-intelligent-addressable-facp-with-communicator","title":"Notifier NFW-100X Intelligent Addressable FACP with Communicator","description":"\u003cp\u003e\u003cstrong\u003eNOTIFIER NFW-100X (FireWarden-100X)\u003c\/strong\u003e — an intelligent addressable fire alarm control panel with a pre-installed dual-technology communicator, supporting one SLC loop and up to 198 addressable devices.\u003c\/p\u003e\n\u003cp\u003eThe FireWarden-100X is the latest intelligent addressable FACP within the FireWarden Series and is a direct replacement for the FireWarden-100 (NFW-100). It supports up to 198 addressable devices (99 detectors and 99 modules), and programs just like FireWarden-100 products, yet fits into applications previously served only by conventional panels.\u003c\/p\u003e\n\u003cp\u003eThe pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator’s internet monitoring capability sends alarm signals over the Internet, saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained, providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-N.\u003c\/p\u003e\n\u003cp\u003eRemote and local programming of the \u003ca href=\"https:\/\/thefirealarmsupplier.com\/collections\/control-panels\"\u003econtrol panel\u003c\/a\u003e is possible using the FS-Tools Upload\/Download utility. Programming databases can be uploaded or downloaded via the panel’s USB port or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows download or upload of the entire program, history file, walk-test data, current status and system voltages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a quick-install chassis and housed in a metal cabinet. \u003cstrong\u003eWhat ships:\u003c\/strong\u003e the main circuit board with display chassis and transformer, backbox with door, and a plastic bag containing screws, cables, key and related hardware.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent signaling line circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable device capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e198 (99 addressable detectors and 99 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnnunciators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (up to 8 per ANN-BUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashScan® and CLIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC wiring class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle addressable SLC loop meeting NFPA Class B and Class A requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 or 240 VAC, 50\/60 Hz, 3.25 A, auto-sensing — no switch required. Non-power-limited, supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC wire size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 14 AWG (2.00 mm²) with 600 V insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 12 V 18 AH lead-acid batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery charger capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7–18 AH (cabinet holds a maximum of two 18 AH batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification appliance circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour, Style Y (Class B) or Style Z (Class A), power-limited and supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum signaling current per circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A special application, 250 mA regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal 24 VDC system power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 A maximum, shared between all NAC circuits and the ANN-BUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC end-of-line resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7k ohm, ½ watt (P\/N 71252, UL listed) for Style Y (Class B); system capable of a 1.9k to 22k ohm ELR range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo programmable Form-C relays and one fixed trouble relay; non-power-limited, non-supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay contact rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral 80-character backlit LCD; 16-key alphanumeric pad; four programmable function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.26\" (48.92 cm) high x 16.82\" (42.73 cm) wide x 0.72\" (1.82 cm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackbox dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.00\" (48.26 cm) high x 16.65\" (42.29 cm) wide x 5.25\" (13.34 cm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.9 lbs. (12.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.00\" (50.80 cm) high x 22.5\" (57.15 cm) wide x 8.5\" (21.59 cm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32–120°F (0–49°C), relative humidity 93% ± 2% non-condensing at 90°F ± 3°F (32°C ± 2°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eListed to UL Standard 864, 10th edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCSFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7165-0028:0505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFDNY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOA #6268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery size is capped by the cabinet:\u003c\/strong\u003e the charger handles 7–18 AH and the FireWarden-100X cabinet holds a maximum of two 18 AH batteries. Larger batteries require the CHG-75 (25–75 AH) or CHG-120 (55–120 AH) and a separate battery box — the BB-26 or NFS-LBB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBudget NAC power as a shared pool:\u003c\/strong\u003e each circuit is rated 2.5 A special application, but total 24 VDC system power shared between all four NACs and the ANN-BUS is 2.7 A. Sizing all four circuits at their individual maximum will exceed the panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffline programming needs ethernet:\u003c\/strong\u003e FS-Tools lets you build the entire program in the office, but offline programming requires an ethernet connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-programming catches address collisions:\u003c\/strong\u003e learn mode reduces installation time and reports two devices set to the same address.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSLC wiring:\u003c\/strong\u003e shielded wire is not required, but all SLC wiring should be twisted-pair to minimize electrical interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary and reverse-polarity signaling:\u003c\/strong\u003e NFPA 72 AUXILIARY service and reverse polarity signaling of alarm and trouble both require the 4XTM transmitter module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended room conditions:\u003c\/strong\u003e although the system meets NFPA requirements across its full range, battery and component life are best in a normal room temperature of 60–80°F (15–27°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFW-100\u003c\/strong\u003e (FireWarden-100) — the previous-generation panel this model directly replaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPOTS-COM\u003c\/strong\u003e — the dual-technology POTS and IP communicator pre-installed in this panel; also sold as a replacement board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCELL-MOD \/ CELL-CAB-N\u003c\/strong\u003e — optional GSM central station communicators over AlarmNet®.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePWRMOD24\u003c\/strong\u003e — power expander module that increases alarm power output to 6 amps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4XTM\u003c\/strong\u003e — reverse polarity transmitter module for local energy municipal box, alarm and trouble.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN-ANN-80 \/ N-ANN-100R\u003c\/strong\u003e — remote LCD annunciators that mimic the panel display.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the NOTIFIER data sheet \"NFW-100X Intelligent Addressable FACP with Communicator,\" document DN-60959:C (7\/16\/2018). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":44262749110496,"sku":"NFW-100X","price":1873.85,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/notifier-control-panels-default-title-notifier-nfw-100x-intelligent-addressable-facp-with-communicator-31950597849312.jpg?v=1769707872"},{"product_id":"notifier-nfw-50x-fire-alarm-control-panel-black","title":"Notifier NFW-50X Fire Alarm Control Panel Black","description":"\u003cp\u003e\u003cstrong\u003eNOTIFIER NFW-50X (FireWarden-50X)\u003c\/strong\u003e — intelligent addressable fire alarm control panel with one SLC loop and a pre-installed IPOTS-COM communicator, in the black cabinet.\u003c\/p\u003e\n\u003cp\u003eThe FireWarden-50X is the latest intelligent addressable FACP within the FireWarden Series and is a direct replacement for the FireWarden-50 (NFW-50). It supports up to 50 addressable devices in any combination of detectors or modules, and programs just like FireWarden-100 products while fitting applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology communicator: the POTS side transmits system status to a central station over the public switched telephone network, while the IP side sends alarm signals over the internet, saving the monthly cost of two dedicated business telephone lines. The secondary telephone line may be retained as backup but is not required, and optional cellular reporting is available with the CELL-MOD or CELL-CAB-N over AlarmNet. The panel ships as a main circuit board with display, the pre-installed communicator, a chassis with transformer, and a backbox with door, plus a bag of screws, cables and the key. Programming is done at the built-in programmer or offline with the FS-Tools Windows utility, uploaded and downloaded through the panel USB port or over ethernet; the USB port also takes a flash drive for the whole program, history file, walk-test data, current status and system voltages.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent signaling line circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressable device capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 (any combination of addressable detectors and modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable software zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnnunciators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (up to 8 per ANN-BUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashScan and CLIP; NFPA Class B and Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 or 240 VAC, 50\/60 Hz, 3.25 A, auto-sensing (no switch required); minimum 14 AWG (2.00 mm²) with 600 V insulation; non-power-limited, supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 12 V 18 AH lead-acid batteries; charger capacity 7–18 AH (cabinet holds a maximum of two 18 AH batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification appliance circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo, Style Y (Class B) or Style Z (Class A), independently programmable; power-limited, supervised; special application power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum signaling current per circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A special application, 250 mA regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal 24 VDC system power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 A maximum, shared between all NAC circuits and the ANN-BUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC end-of-line resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7k ohm, ½ watt (P\/N 71252 UL listed) for Style Y (Class B); system capable of a 1.9 kΩ – 22 kΩ ELR range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo programmable Form-C relays and one fixed trouble relay; 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive); non-power-limited, non-supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral 80-character backlit LCD; 16-key alphanumeric pad; four programmable function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHistory file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.26 in. (48.92 cm) high x 16.82 in. (42.73 cm) wide x 0.72 in. (1.82 cm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackbox\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.00 in. (48.26 cm) high x 16.65 in. (42.29 cm) wide x 5.25 in. (13.34 cm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrim ring (TR-CE\/B)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.00 in. (55.88 cm) high x 19.65 in. (49.91 cm) wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight and dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.9 lbs. (12.20 kg); 20.00 in. x 22.5 in. x 8.5 in. (50.80 x 57.15 x 21.59 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature and humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets NFPA requirements for 0–49°C (32–120°F) and 93% ± 2% RH non-condensing at 32°C ± 2°C (90°F ± 3°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eListed to UL Standard 864, 10th edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency listings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL S635; CSFM 7165-0028:0505; FDNY COA #6268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eInstallation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.7 A is the real ceiling:\u003c\/strong\u003e each NAC can deliver 2.5 A special application, but the maximum total 24 VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A. Size notification loads against that total, not against 2.5 A per circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity is limited by the cabinet:\u003c\/strong\u003e the on-board charger covers 7–18 AH and the FireWarden-50X cabinet holds a maximum of two 18 AH batteries. Batteries larger than 18 AH require the CHG-75 or CHG-120 external charger and a separate battery box (BB-26 or NFS-LBB).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack versus red:\u003c\/strong\u003e the NFW-50X is the black cabinet and takes the DP-ES-B dress panel and TR-CE-B trim ring. The red NFW-50XR takes the DP-ES-R and TR-CE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffline programming needs ethernet:\u003c\/strong\u003e the entire program can be created in the office with FS-Tools, but offline programming requires an ethernet connection. FS-Tools is a free download from notifier.com.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary and reverse-polarity signalling:\u003c\/strong\u003e NFPA 72 Auxiliary service and reverse polarity signalling of alarm and trouble both require the 4XTM transmitter module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e shielded wire is not required, but all SLC wiring should be twisted-pair to minimise electrical interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended environment:\u003c\/strong\u003e although the panel meets NFPA requirements to 49°C, battery and component life is best in a normal room temperature of 15–27°C (60–80°F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFW-50XR\u003c\/strong\u003e — the identical panel in the red cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFW-50\u003c\/strong\u003e — the FireWarden-50, which the NFW-50X directly replaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPOTS-COM\u003c\/strong\u003e — the dual technology POTS and IP communicator, available as a replacement board. \u003cstrong\u003eCELL-MOD \/ CELL-CAB-N\u003c\/strong\u003e — optional GSM communicators over AlarmNet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN-ANN-80 \/ N-ANN-100\u003c\/strong\u003e — remote LCD annunciators that mimic the panel display. \u003cstrong\u003eN-ANN-I\/O\u003c\/strong\u003e, \u003cstrong\u003eN-ANN-LED\u003c\/strong\u003e, \u003cstrong\u003eN-ANN-RLED\u003c\/strong\u003e, \u003cstrong\u003eN-ANN-RLY\u003c\/strong\u003e, \u003cstrong\u003eN-ANN-S\/PG\u003c\/strong\u003e — graphic driver, LED, relay and printer gateway modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4XTM\u003c\/strong\u003e — reverse polarity \/ city box transmitter module with disable switch and disable trouble LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBB-XP \/ BB-25 \/ CHS-6\u003c\/strong\u003e — module cabinets and chassis. \u003cstrong\u003eBB-26 \/ NFS-LBB \/ CHG-75 \/ CHG-120\u003c\/strong\u003e — battery boxes and chargers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFS-Tools\u003c\/strong\u003e — Windows programming and upload\/download utility. \u003cstrong\u003eSWIFT wireless\u003c\/strong\u003e devices are supported via the FWSG gateway.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications taken from the NOTIFIER data sheet “NFW-50X Intelligent Addressable FACP with Communicator,” document DN-60955:C (7\/16\/2018). Manufacturer specifications are subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":44262749176032,"sku":"NFW-50X","price":1550.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/notifier-control-panels-default-title-notifier-nfw-50x-fire-alarm-control-panel-black-35052993380576.jpg?v=1763283798"},{"product_id":"notifier-nfc-50dae-50-watt-amplifier","title":"Notifier NFC-50DAE 50-Watt Amplifier","description":"\u003ch2\u003eThe Notifier FirstCommand NFC-50DAE is a 50 watt amplifier.\u003c\/h2\u003e\n\u003cp\u003eIt has a built-in power supply and battery charger that supports up to 35 AH. For batteries larger than 18 AH, the BB-26 or NFS-LBB Battery Box can be used.\u003c\/p\u003e\n\u003cp\u003eThe Notifier FirstCommand NFC-50\/100 is a single channel, 50 watt, 25 VRMS. It's a multipurpose emergency voice evacuation panel for fire applications and mass notification applications.\u003c\/p\u003e\n\u003cp\u003eThe Notifier FirstCommand NFC-50\/100E is a multi-purpose emergency voice evacuation panel for fire applications.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":44262749241568,"sku":"NFC-50DAE","price":1243.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/notifier-control-panels-default-title-notifier-nfc-50dae-32094605213920.jpg?v=1763283834"},{"product_id":"notifier-rp-2002-ul-listed-six-zone-fire-alarm-control-panel","title":"Notifier RP-2002 Six-Zone Agent Release Control Panel, Single and Dual Hazard","description":"\u003cp\u003e\u003cstrong\u003eNotifier RP-2002\u003c\/strong\u003e — a six zone agent release control panel, not an ordinary fire alarm panel.\u003c\/p\u003e\u003cp\u003eIts purpose is to discharge a suppression agent. Notifier designs it to NFPA 12, 12A, 12B and 2001, covering carbon dioxide, Halon 1301, Halon 1211 and clean agent, in single or dual hazard configurations. Detection uses conventional circuits; the release logic, timers and abort handling are the point.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSix Class B initiating device circuits, zones 1 to 5 on TB4 and zone 6 on TB6; Class A via N-CAC-5X\u003c\/li\u003e\n\u003cli\u003eFour outputs, each programmable as a notification appliance circuit or a releasing circuit, within 7.0 A total\u003c\/li\u003e\n\u003cli\u003eAdjustable pre-discharge, discharge and waterflow timers, cross-zone interlock, programmable abort\u003c\/li\u003e\n\u003cli\u003eDisable and enable control per input and per output zone, with extensive transient protection\u003c\/li\u003e\n\u003cli\u003eListed to UL 864 9th Edition, FM approved, CSFM 7165-0028:0245; stated to meet IBC seismic\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eIt ships with back box, power supply and manual; agent solenoids, NBG-12LR agent release pull stations, batteries of 7 to 26 Ah and the SEISKIT-COMMENC seismic kit are not. RP-2002E is the 220\/240 VAC version.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":44262749307104,"sku":"RP-2002","price":1472.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/products\/notifier-control-panels-default-title-notifier-rp-2002-ul-listed-six-zone-fire-alarm-control-panel-32054326984928.jpg?v=1763283795"},{"product_id":"notifier-cpu2-3030nd-sp","title":"Notifier CPU2-3030ND-SP CPU for a NFS23030 System, NO Displayspanish","description":"\u003ch2\u003eNotifier CPU2-3030ND-SP CPU2-3030 without display, Spanish version\u003c\/h2\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":44262749896928,"sku":"CPU2-3030ND-SP","price":3218.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0653\/7186\/5312\/files\/notifier-control-panels-default-title-notifier-cpu2-3030nd-sp-34167378837728.jpg?v=1763283809"}],"url":"https:\/\/thefirealarmsupplier.com\/collections\/control-panels.oembed?page=9","provider":"The Fire Alarm Supplier","version":"1.0","type":"link"}